Smeg KSEU912X Скачать руководство пользователя страница 10

 

 

 

 

 

EN 

1

10 

ELECTRICAL CONNECTION 

•  Remove the cover from the Field Wiring Compartment with a 

phillips screwdriver. 

•  Feed the Power Supply Cable through the electrical knockout. 

Connect the Power Supply Cable to the range- hood cable.  At-
tach the Power Supply Cable grounding lead to the green screw 
provided. Attach the White lead of the power supply to the 
White lead of the rangehood with a twist-on type wire con-
nector. Attach the Black lead of the power supply to the Black 
lead of the rangehood with a twist-on type wire connector. 

• Replace the cover. 

 

 

 

Chimney assembly 

Upper exhaust chimney

 

•  Slightly widen the two sides of the upper flue and hook them 

behind the brackets 

7.2.1

, making sure that they are well seat-

ed. 

•  Secure the sides to the brackets using the 4 screws 

12c

 sup-

plied. 

 

Lower exhaust chimney

 

•  Slightly widen the two sides of the flue and hook them be-

tween the upper flue and the wall, making sure that they are 
well seated. 

•  Fix the lower part laterally to the hood body using the 2 screws 

12c

 supplied. 

•  On the recirculation version, fit the directional grids 

8a – 8b

 in 

their housings making sure that the directional symbols are to-
wards the top and front of the hood. Also make sure that they 
are correctly inserted in the connection extension pieces 

14.1

 

 

12c

8a

2.1

2.2

2

8b

7.2.1

12c

Power supply cable

Green

Ground

screw

Ground wire

Содержание KSEU912X

Страница 1: ...Manuel d Instructions Instructions Manual Manual de instrucciones Libretto Istruzioni KSEU912X ...

Страница 2: ...EN 2 2 INDEX WARNINGS AND REQUIREMENTS 3 RECOMMENDATIONS AND SUGGESTIONS 6 DIMENSIONS and MAIN PARTS 7 INSTALLATION 8 USE 11 CARE 12 ...

Страница 3: ...ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED MUST BE SEALED This rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured H...

Страница 4: ...cy Massachusetts 02269 This appliance should be connected directly to the fused disconnect or circuit breaker through flexible armored or nonmetallic sheathed copper cable Allow some slack in the cable so the ap pliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the power supply cable at the appliance and at the junction box When m...

Страница 5: ...he American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors W A R N I N G Electrical ground is required on this rangehood If cold water pipe is interrupted by plastic nonmetallic gaskets or ...

Страница 6: ...e kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air USE The range hood has been designed exclusively for domestic use to eliminate kitchen odors Never use the hood for purposes other than for which it has ben designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the...

Страница 7: ...Aria 8b 1 Left Air Outlet Grill Aria 10 1 Damper 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs if supplied 12a 6 Screws 3 16 x 1 3 4 12c 6 Screws 1 8 x 3 8 Q ty Documentation 1 Instruction Manual 5 1 8 2 7 16 35 3 8 12 3 1 2 12 1 2 21 1 4 2 3 8 10 5 8 19 5 16 Min 35 Max 38 1 8 11 12a ...

Страница 8: ...on the wall as shown at X below the first bracket X height of the up per chimney section supplied aligning the center notch with the vertical line Mark the wall at the centers of the holes in the bracket Mark a reference point as indicated at 4 9 16 from the vertical reference line and 13 3 8 above the horizontal reference line Repeat this operation on the other side Drill ø 5 16 holes at all the ...

Страница 9: ...T SYSTEM When installing the ducted version connect the hood to the chimney using a rigid 6 duct Install the damper 10 ø 6 Fix the duct in position using sufficient pipe clamps not sup plied DUCTLESS VERSION AIR OUTLET Push fit connection 15 onto the hood body outlet Insert the connection extension pieces laterally 14 1 in connec tion 15 Make sure that the outlet of the extension pieces 14 1 is ho...

Страница 10: ...exhaust chimney Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seat ed Secure the sides to the brackets using the 4 screws 12c sup plied Lower exhaust chimney Slightly widen the two sides of the flue and hook them be tween the upper flue and the wall making sure that they are well seated Fix the lower part laterally to the hood...

Страница 11: ...sible to set the delayed shutdown of the hood to 30 minutes This function is suitable for a complete elimination of residual cooking odours Functioning only when the motor is on not during the 24H function or intensive function The suction speed and a dot flash once a second By pressing the key the function is stopped Pressing and holding the button for 5 seconds enables the remote control Pressin...

Страница 12: ...e of the hood Alarm reset Press the G key for at least 3 seconds See Use Paragraph Cleaning Remove the filters one at a time supporting them with one hand and turning the safety knobs pull and turn Wash the filters Pay attention not to bend them Make sure that filters are completely dry before putting them into their seat Place the filters again into their seats and make sure that the handle of th...

Страница 13: ...flash once and show FC charcoal filter saturation alarm DEACTIVATED SUBSTITUTION OF THE CHARCOAL FILTER Alarm reset Switch off the motor and the lighting system Press the G key for at least 3 seconds See Use Paragraph Substitution of the filter Remove the metal grease filters Remove the charcoal filter as indicated in the picture Place the filter again into its seat Place again the metal grease fi...