Smeg KSET900X Скачать руководство пользователя страница 5

 

installation. If it not fitted with a plug (direct mains connection) 
or if the plug is not located in an accessible area, after 
installation,  apply a double pole switch in accordance with 
standards which assures the complete disconnection of the 
mains under conditions relating to over-current category III, in 
accordance with installation instructions. 

Warning!

 Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that 
the mains cable is correctly assembled. 

 

Mounting 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must 
verify suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take 
the weight of the hood. 

Do not tile, grout or silicone this 

appliance to the wall. Surface mounting only. 

This hood is designed for fitting in a cabinet or on some other 
support. 
The diameter of the ventilation duct must be the same as the 
that of the flange mounted on the ventilation hole on the hood. 
To mount the hood proceed as follows: 

Position the drilling template inside the left cupboard on 
the right hand side with the arrow point towards the back 
on the cupboard. 

Drill the holes marked on the template. 

Repeat the procedure for the right hand cupboard 

If the sides of the cupboards are 18 mm thick, insert 4 
spacers 

Z

 on the sides of the hood. 

Fix the hood to the cupboard using four screws 

N

Fig. 8 

 

Additional instructions for the montage 

Box adjustement 

The hood can be installed in cabinets with different depths, 
the front of the box must always be in line with the cabinet. 
For alignment adjust the back stops of the box. For box 
adjustment, loosen screws “

M

” and slide square plates “

G

” as 

necessary and tighten screws “

M

”. 

Fig. 9 

 

Description of the hood 

Fig. 1.1 
1. 

Light Switch 

2. 

Motor Speed Switch 

3. 

Illumination of the cooking surface 

4. 

Grease Filters/grease filter support grate 

 

5.

  Light Cover Supports  

6.

 Pull-Out 

Drawer 

Model with Grease Filter Support Grate 

Opening the Grease Filter Support Grates

 - Fig. 2.1 

a.

  Remove the pull-out drawer completely. 

b.

 Push 

the 

A

 knobs inwards toward each other (in the 

“Open” direction as indicated on the plastic knob itself). 

c.

  To remove the grates completely, use the 

B

 spring 

fasteners, which act as pins to hold the grate in place 
(Fig. 3). 

 

Model with Self-supporting Metal Filters 

Removing the Grease Filters

 - Fig. 2.2 

a.

  Remove the pull-out drawer completely. 

b. 

Press the side handles 

C

 (some models are supplied with 

handles Z - Fig. 2.3) towards the opposite side and 
remove the filters. 

Putting the Filters Back in Place

 

a.

  Remove the pull-out drawer completely and mount the 

grease filter so that it covers the drawer. 

b.

  Close the drawer and install the remaining grease filter. 

Opening the Light Cover Support

 

a.

  Remove the pull-out drawer completely. 

b.

   According to model in possession: 

 Lamp 

D

 with hook locks type 

A

 - Fig.2.2 

 

Move the bracket hook locks towards each other  (in 
direction “Open” as printed on the plastic part of the lock). 
Lamp 

F

 with hook locks type 

S

 - Fig. 1.2 

 

Move the hook locks as indicated by the arrows and 
completely remove the lamp from the housing (Fig. 1.3). 

 

Operation 

The hood is fitted with a control panel with aspiration speed 
selection control and a light switch to control cooking area 
lights. 
Use the high suction speed in cases of concentrated kitchen 
vapours.  It is recommended that the cooker hood suction is 
switched on for 5 minutes prior to cooking and to leave in 
operation during cooking and for another 15 minutes 
approximately after terminating cooking.  

 

Maintenance 

ATTENTION! 

Before performing any maintenance operation, 

isolate the hood from the electrical supply by switching off at 
the connector and removing the connector fuse.  
Or if the appliance has been connected through a plug and 
socket, then the plug must be removed from the socket. 

 

Cleaning 

The cooker hood should be cleaned regularly (at least with the 
same frequency with which you carry out maintenance of the 
fat filters) internally and externally.  Clean using the cloth 
dampened with neutral liquid detergent. Do not use abrasive 
products. 

DO NOT USE ALCOHOL!

 

WARNING: 

Failure to carry out the basic cleaning 

recommendations of the cooker hood and replacement of the 
filters may cause fire risks.  
Therefore, we recommend oserving these instructions. 
The manufacturer declines all responsibility for any damage to 
the motor or any fire damage linked to inappropriate 
maintenance or failure to observe the above safety 
recommendations. 

 

Grease filter 

Traps cooking grease particles. 

 

If situated inside the support grill, it may be one of the 
following types:  

Paper filter 

 must be replaced once a month or if colouring 

appears on upper side, in such cases the colouring is evident 
through the grill openings.  

Содержание KSET900X

Страница 1: ...de montage et mode d emploi NL Montagevoorschriften en gebruiksaanwijzingen SV Monterings och bruksanvisningar IT Istruzioni di montaggio e d uso ES Montaje y modo de empleo PT Instruções para montagem e utilização RU Инструкции по монтажу и эксплуатации TR Montaj ve kullanõm talimatlarõ ...

Страница 2: ......

Страница 3: ......

Страница 4: ...tenance instructions provided in this manual Failure to follow the instructions provided in this user guide regarding the cleaning of the hood and filters will lead to the risk of fires Do not use or leave the hood without the lamp correctly mounted due to the possible risk of electric shocks We will not accept any responsibility for any faults damage or fires caused to the appliance as a result o...

Страница 5: ...hich act as pins to hold the grate in place Fig 3 Model with Self supporting Metal Filters Removing the Grease Filters Fig 2 2 a Remove the pull out drawer completely b Press the side handles C some models are supplied with handles Z Fig 2 3 towards the opposite side and remove the filters Putting the Filters Back in Place a Remove the pull out drawer completely and mount the grease filter so that...

Страница 6: ...l in possession indicates this necessity To fit or replace a carbon filter a Request a charcoal filter from the retailer specifying the model and type of hood Caution Some charcoal filters come covered with a plastic film to protect their filtering properties If this is the case remove the film before installing the filter b Remove the pull out drawer completely c Remove the grease filters or the ...

Отзывы: