Mounting the hood body 

•  Remove  the  metal  grease  filters  by  turning  the  handles  pro-

vided. 

•  Adjust the two screws 

Vr

, on brackets 

11a

, to a minimum. 

•  Hook the hood canopy onto the two brackets 

11a.

 

•  From inside the hood canopy, adjust the screws 

Vr

 to set the 

Hood Canopy level. 

•  Tighten the safety screws 

12a

 

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When  installing  the  ducted  version,  connect  the  hood  to  the 

chimney using either a flexible or rigid pipe ø 150 or 120 mm, 

the choice of which is left to the installer. 

•  To  install  a  ø  120  mm  air  exhaust  connection,  insert  the  re-

ducer flange 

9

 on the hood body outlet. 

•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

•  Remove possible charcoal filters. 

 

ø 150

9

ø 120

RECIRCULATION VERSION AIR OUTLET 

•  Insert the connection extension pieces laterally 

14.1

 in connec-

tion 

15.

 

•  Insert the Connector 

15

 into the Support bracket 

7.3

 and fix it 

with a screw. 

•  Make sure that the outlet of the extension pieces 

14.1

 is hori-

zontally and vertically aligned with the chimney outlets.  

•  Connect  the  air  outlet  connection 

15

  to  the  hood  body  outlet 

using either a flexible or rigid pipe   ø 150 mm, the choice of 

which is left to the installer. 

•  Ensure that the activated charcoal filters have been inserted. 

 

15

ø 150

14.1

7.3

Содержание KQR45BE

Страница 1: ...i Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Brugsvejledning Bruksanvisning Instrukcja Obs ugi Bruksanvisning K ytt oh...

Страница 2: ...E CONSEILS ET SUGGESTIONS 25 CARACTERISTIQUES 28 INSTALLATION 29 UTILISATION 32 ENTRETIEN 33 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 35 CHARAKTERISTIKEN 38 MONTAGE 39 BEDIENUNG 42 WARTUNG 43 INHO...

Страница 3: ...79 BRUG 82 VEDLIGEHOLDELSE 83 INNHOLD ANBEFALINGER OG FORSLAG 85 EGENSKAPER 88 INSTALLASJON 89 BRUK 92 VEDLIKEHOLD 93 95 98 99 102 103 SPIS TRE CI UWAGI I SUGESTIE 105 W A CIWO CI TECHNICZNE 108 INSTA...

Страница 4: ...4 4 SIS LT OHJEET JA SUOSITUKSET 125 MITAT JA OSAT 128 ASENNUS 129 K YTT 132 HUOLTO 133 135 138 139 142 143 FI SA...

Страница 5: ...ect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustio...

Страница 6: ...rposes other than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sur...

Страница 7: ...eavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indica...

Страница 8: ...chimney 9 1 Reduction flange 150 120 mm 14 1 2 Air Outlet Connector Extension 15 1 Air Outlet Connector 19 1 Chimney Fixing Element Ref Q ty Components for Installation 7 2 1 2 Upper Chimney Fixing B...

Страница 9: ...vided aligning its centre grooves with the vertical reference line Mark the centres of the holes in the bracket Mark a reference point as indicated at 105 mm from the horizontal reference line Drill t...

Страница 10: ...a 120 mm air exhaust connection insert the re ducer flange 9 on the hood body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 150 9 120 RECI...

Страница 11: ...pen the two side pieces out slightly hook them up behind the brackets 7 2 1 and bring them back together again until they are in contact Fix to the Brackets at the sides using 4 screws 12c 2 9 x 9 5 p...

Страница 12: ...perating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the optimum...

Страница 13: ...ilters taking care not to bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version Th...

Страница 14: ...ILCOS Code 28 E14 220 240 104 x 35 HSGSB C UB 28 220 240 E14 20 G4 12 33 x 9 HSG C UB 20 12 G4 35 GU10 230 51 x 50 7 HAGS 35 230 GU10 51 40 50 GU10 230 51 x 50 7 HAGS 35 230 GU10 51 20 20 GU4 12 40 x...

Отзывы: