RECOMMENDATIONS AND SUGGESTIONS

The Instructions for Use apply to several versions of this appliance. Accord-
ingly, you may find descriptions of individual features that do not apply to 
your specific appliance. 

INSTALLATION 
•  The manufacturer will not be held liable for any damages resulting from in-

correct or improper installation. 

•  The minimum safety distance between the cooker top and the extractor 

hood is 650 mm (some models can be installed at a lower height, please re-
fer to the paragraphs on working dimensions and installation). 

•  Check that the mains voltage corresponds to that indicated on the rating 

plate fixed to the inside of the hood. 

•  For Class I appliances, check that the domestic power supply guarantees 

adequate earthing. 

  Connect the extractor to the exhaust flue through a pipe of minimum diame-

ter 120 mm. The route of the flue must be as short as possible. 

•  Do not connect the extractor hood to exhaust ducts carrying combustion 

fumes (boilers, fireplaces, etc.). 

•  If the extractor is used in conjunction with non-electrical appliances (e.g. gas 

burning appliances), a sufficient degree of aeration must be guaranteed in 
the room in order to prevent the backflow of exhaust gas. The kitchen must 
have an opening communicating directly with the open air in order to 
guarantee the entry of clean air.  

USE
•  The extractor hood has been designed exclusively for domestic use to elimi-

nate kitchen smells. 

•  Never use the hood for purposes other than for which it has been designed. 
•  Never leave high naked flames under the hood when it is in operation. 
•  Adjust the flame intensity to direct it onto the bottom of the pan only, making 

sure that it does not engulf the sides. 

•  Deep fat fryers must be continuously monitored during use: overheated oil 

can burst into flames. 

•  Do not flambè under the range hood; risk of fire  
•  This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision or instruction concern-
ing use of the appliance by a person responsible for their safety. 

•  Children should be supervised to ensure that they do not play with the appli-

ance. 

MAINTENANCE 
•  Switch off or unplug the appliance from the mains supply before carrying out 

any maintenance work. 

•  Clean and/or replace the Filters after the specified time period (Fire hazard). 
•  Clean the hood using a damp cloth and a neutral liquid detergent. 

The symbol 

 on the product or on its packaging indicates that this product may not be treated 

as household waste. Instead it shall be handed over to the applicable collection point for the 
recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, 
you will help prevent potential negative consequences for the environment and human health, 
which could otherwise be caused by inappropriate waste handling of this product. For more 
detailed information about recycling of this product, please contact your local city office, your 
household waste disposal service or the shop where you purchased the product. 

550 mm min.

Содержание KQ45X

Страница 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning KQ45X...

Страница 2: ...CONSEILS ET SUGGESTIONS 20 CARACTERISTIQUES 21 INSTALLATION 22 UTILISATION 25 ENTRETIEN 26 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 28 CHARAKTERISTIKEN 29 MONTAGE 30 BEDIENUNG 33 WARTUNG 34 INHOU...

Страница 3: ...DICE CONSELHOS E SUGEST ES 52 CARACTER STICAS 53 INSTALA O 54 UTILIZA O 57 MANUTEN O 58 60 61 62 65 66 INNEH LL REKOMMENDATIONER OCH TIPS 68 EGENSKAPER 69 INSTALLATION 70 ANV NDING 73 UNDERH LL 74 PT...

Страница 4: ...er than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it...

Страница 5: ...ty Product components 1 1 Hood Body complete with Controls Light Suction Unit Filters Lower Duct 7 1 PVC Pipe fitted 8 1 Inclinable grid fitted 9 1 Reduction flange 150 120 mm 10 1 Metal cover Ref Q...

Страница 6: ...e maining between the hood and the upper limit ceiling or self is at least 8 10 cm On the wall trace a vertical line up to the ceiling or top limit at the centre of the area where you intend to fit th...

Страница 7: ...y in case the connecting diameter is 150 REAR AIR OUTLET When drilling the air outlet hole in the wall proceed in accor dance with the scheme in the part concerning the wall drilling Use a pair of ton...

Страница 8: ...grid 8 on the air outlet Make sure that the position of the grid is correct Make sure that charcoal filters have been placed inside the hood 8 7 ELECTRICAL CONNECTION Connect the hood to the mains th...

Страница 9: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Страница 10: ...r more frequently if use is particularly intensive Resetting the alarm signal Press any of the buttons except the Light button Cleaning the Filters Remove the Filters one at a time supporting them wit...

Страница 11: ...sh once Activated Charcoal Filter saturation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter R...

Отзывы: