INSTALLATION INSTRUCTIONS:

The hood is supplied with all the accessories necessary for 

its installation. 

The minimum distance between the lower 

surface of the hood and the hob must be at least 750 mm 

for  gas  hobs  and  650mm  for  electric  hobs

    (Fig.  1  ). 

If 

the motor inlet is equipped with a  non-return valve for 

fumes, make sure it can open and close freely.

For easy installation it is recommended to follow the procedures 

described below: 

1) The hood must be centred with respect to the hob surface.

2) There  are  different  installation  procedures  depending  on 

the hood model. Choose one of the following fixing systems 

(Fig.2):

a)  2  levelling  hooks  that  fasten  on  with  the  supplied 

expansion plugs

b)  Rear levelling bracket that fastens on with the supplied 

expansion plugs

c)  Levelling anchors on motor box that fasten on with the 

supplied expansion plugs

d)  For  island  models  refer  to  the  special  installation 

attachment.

N.B.: Fixing systems a) and b) fit on to the back of the hood 

in the holes L1 (Fig. 4 ).

3) Remove the grease filters and position the hood on the wall 

and mark the reference position for the holes to anchor the 

relative fixing system.

4) Drill the 2 holes previously marked after removing the hood 

from the wall

5) Anchor  the  fixing  system  to  the  wall  by  tightening  the 

expansion plug

6) Mark holes L2 on the wall to secure the plugs safely in the 

holes. (plugs supplied)

7) Hang  the  hood  on  the  fixing  system  (fig.  2)  and  level  it 

using the adjustment screws ( fig.2 ).

8) Securely fix the hood by fully tightening the two expansion 

screws of the holes L2

AIR CONNECTION SYSTEMS:

EXTRACTION  version: 

  Connect  the  fume  expulsion  duct 

(inside diameter 150 mm.) to the exhaust of the motor inlet. 

If the expulsion duct is D.120mm, use the special reduction 

flange  (F)  supplied,  where  applicable.  The  expulsion  duct 

must not have a diameter of less than 120 mm. 

Note that if the hood is supplied with an active carbon 

filter, this must be removed (see page 8)

Deviation for Germany:

When the hood and other appliances powered by energy other 

than electricity are simultaneously ON, the negative pressure 

in the room must not exceed 4 Pa (4 x 10-5 bar).

Содержание KD120XE

Страница 1: ...ng DA Manual de instrucciones ES Instrukcja PL Manual de lnstru es PT Instructiehandleiding NL Bruksanvisning NO RU Instruktionshandbo SV Ohjekirja FI Questo manuale d istruzione fornito da trovaprezz...

Страница 2: ...tracted air must not be conveyed in a duct used to conduct fumes from appliances powered by gas or other fuel Connect the outlet for the air extracted by the hood to fumes discharge ducts with a suita...

Страница 3: ...t supervision THE MANUFACTURER DECLINES ALL RESPONSIBILITY IF THE ABOVE INDICATIONS ARE NOT FOLLOWED USE This appliance was designed to be used as an EXTRACTION extraction of air to the outside or FIL...

Страница 4: ...hood in the holes L1 Fig 4 3 Remove the grease filters and position the hood on the wall and mark the reference position for the holes to anchor the relative fixing system 4 Drill the 2 holes previou...

Страница 5: ...of diameter D 150mm FLUE ASSEMBLY fig 6 Position the flue bracket K to the required top limit Mark the two holes on the wall to fix the bracket Drill and fix the bracket with the supplied expansion pl...

Страница 6: ...rt cooking and to keep it on for at least 15min after you have finished cooking or until steam and odours have completely disappeared To start the hood identify the command type of the hood and then f...

Страница 7: ...s when all loads are off Motor Light holding key B down during the animation the Active Carbon Filters Alarm switches On Off Displays a rotary animation for 5 seconds EF flashes twice in activation EF...

Страница 8: ...splayed by the LED located under the key flashing When Keyboard lock On CONTROL PANEL KEY FUNCTION DISPLAY A SWITCH THE SUCTION MOTOR ON OFF DISPLAYS THE SET SPEED B DECREASE THE OPERATING SPEED DISPL...

Страница 9: ...e product It is advisable to clean the hood by always rubbing the steel in the direction of the surface finish TIMED AUTO POWER OFF By pressing one of the motor speed keys 2 3 twice you will activate...

Страница 10: ......

Страница 11: ...ilters are capable of retaining odours until the carbon reaches saturation level They cannot be washed and they are not renewable therefore it is recommended to replace them at least every six months...

Страница 12: ...n lamps a WITH LED LIGHTS The LED lights guarantee a significant number of hours of operation Should it be replace due to being worn or faulty the entire spotlight must be replaced In this case contac...

Страница 13: ...rate collection of waste electrical and electronic equipment As an alternative to autonomous disposal the device you want to dispose of can be given back to the retailer at the time of purchasing new...

Страница 14: ...EN 12...