Smeg KCVR9NE Скачать руководство пользователя страница 5

EN 

KCVR9NE 

 

Electronic control system instructions for use: 

 

Technical Features: 

• 

Power supply from mains: 

230 VAC – 50/60 Hz 

• 

Power consumption in standby: 

20 mA 

• 

Max. load applicable to LIGHTS connection: 

150 W 

• 

Max. load applicable to MOTOR connection: 

400 W 

(capacitor motors only) 
• 

Microprocessor-controlled electronic control system. 

• 

Loads managed by solid-state components, opto-isolated from the 

mains. 

• 

Hardware and software EMC filtering. 

• 

Connection to electronic control board by flat cable (10 poles) 

protected by flexible sheath (outside diameter 8 mm). Low voltage 
circuits (5 V). 

• 

Possibility of operating an optional load at mains voltage. 

• 

Non-volatile internal memory (EEPROM) for storing system settings 

and flags. 

• 

Optional analog/digital input for sensor and/or external control. 

• 

Phase-cutting motor control. 

• 

SOFT-START light switch: turn the lights on gradually to guarantee 

better performance of electronic components. 

• 

Automatic sensing of mains frequency: 

number 50 flashing on display = 230 VAC – 50 Hz mains, 
number 60 flashing on display = 230 VAC – 60 Hz mains, 

• 

Software-enabled reception of remote control commands: all the 

hood's main functions can be controlled by an IR remote control  
protected by a propriety code, operating at 24+1 bit and with an IR 
carrier frequency of 36 KHz. 

• 

Software set-up procedure for selecting and permanently storing  

blower motor settings and enabling A.C. filter saturation alarm (for 
filter hoods). 

• 

FILTER saturation alarm and alarm reset control (hour TIMER 

for hood work). 

 
 