Страница 1: ...060 GLASSWARE WASHER USER MANUAL code 914773904 SMEG S p A Via Leonardo da Vinci 4 42016 Guastalla RE Italy Tel 39 0 522 821 1 Fax 39 0 522 821 592 e mail instruments smeg it internet www smeg instrum...
Страница 2: ...ng from those listed below The appliance must only be installed serviced and repaired by Smeg s authorized personnel The warranty provided will immediately become void if the machine issued in ways th...
Страница 3: ...nts smeg it Service E Mail Address Our Sales Department staff will provide information about prices and offers You can examine our entire product range in our Internet web site along with our innovati...
Страница 4: ...16 5 6 SECURITY POLICY USER PASSWORD AND SUPER USER 17 5 7 BUILT IN SOFTENER 19 5 7 1 How to add salt 19 5 7 2 Use of the appliance with softened mains water 20 5 7 3 Forced resin regeneration 21 5 8...
Страница 5: ...SS 31 8 ALARM MESSAGES 37 9 CLEANING AND SERVICING 42 9 1 ROUTINE INSPECTIONS 42 9 2 HOW TO CLEAN THE SPRAYING ARMS 42 9 3 HOW TO CLEAN THE FILTERS 42 9 4 HOW TO CLEAN THE INLET FILTERS 43 9 5 INSPECT...
Страница 6: ...Manuale GW3060 User Versione 22 10 08 6 1 KEY TO THE SYMBOLS USED IN THE MANUAL AND ON THE MACHINE Read with the utmost care Warning danger Warning hot surfaces...
Страница 7: ...d to the applicable reference standards This appliance has been built for the following function Washing various kinds of glassware by means of Chemical Disinfection or Thermal disinfection The applia...
Страница 8: ...al as it depends on the operating mode and will in no way impair the way the appliance operates Discarded appliances must be rendered unusable Cut off the power flex after having detached the terminal...
Страница 9: ...nel is divided into two separate sections The left hand part of the display with keys for starting and stopping a program and for the reset process The right hand part of the display which contains th...
Страница 10: ...er situations such as those after an alarm has occurred ARROW UP selection key ARROW DOWN selection key ARROW LEFT DRYER ON key used to select the separate drying cycle if available it is also used fo...
Страница 11: ...on made program selection door opening INC increases the value in question selects yes ESC quits the current mask and goes back to the previous step DEC decreases the value in question selects no The...
Страница 12: ...e system to initialize after the SMEG logo has appeared the system will access the menu of the selected program e g PLASTIC 70 C in this menu various keys will appear on the bottom line of the display...
Страница 13: ...opened if the temperature is no higher than 40 C or the cycle can be continued The following message will appear once the cycle has terminated The door can be opened and the processed instruments remo...
Страница 14: ...t can be made of the last cycle executed when the machine is in standby mode proceed as follows Press the STOP button The following screen will appear At this point press the ENTER key to print out th...
Страница 15: ...where the list of programs can be scrolled with keys and When the cursor has reached the required program select it and confirm the selection with key The system will now access the menu of the selec...
Страница 16: ...low to open the door find the hole under the lower profile of the door fig 5 6 1 1 insert the screwdriver into the hole push on the screwdriver delicately without forcing until you hear the closing me...
Страница 17: ...rying parameters COPY NEW PROGRAM UTILITY accesses all the sub menus can also change the user passwords WASHING PARAMETERS only certain sub menus as listed below WATER CONNECTION WATER TRAP WASH REGEN...
Страница 18: ...nge the password when the appliance is used for the first time so as to be certain of who is enabled to access the machine see 11 1 The User Control Activation option can be activated to make sure tha...
Страница 19: ...over a period of time The ionic exchange resins of the water softener are regenerated by sodium chloride i e common salt NaCl The only routine maintenance required is to add coarse salt to the reservo...
Страница 20: ...F expressed in French degrees or 8 D expressed in German degrees the regeneration cycle of the built in softener must be inhibited and salt must not be added to the softener Consult chapters xxx How...
Страница 21: ...1 HARDNESS IN F XX 0 HARDNESS IN T XX 0 HARDNESS IN I XX 0 PHASE NUMBER XX 0 5 7 3 Forced resin regeneration Simply enter 0 in the PHASE NUMBER data item in the menu below to make the machine perform...
Страница 22: ...L THE WASHING TROLLEYS The machine is supplied without trolleys The Customer chooses the trolleys he needs from a vast range of available solutions These trolleys are simply placed on the door and all...
Страница 23: ...r of the machine on the right end depending on the machine model there may be 1 or 2 pumps by default Each tube is marked by a tag that indicates the number of the pump and the relative additive it ca...
Страница 24: ...GW4090 Dispenser settings Recommended programming values Product value ap ml cycle PUMP P1 Alkaline detergent 15 25 30 50 PUMP P2 Acid neutralizer 15 20 25 40 PUMP P3 Caustic soda 33 sol approx 45 60...
Страница 25: ...Always avoid long time intervals between this preliminary treatment and the instrument washer treatment as the risk of corrosion exists for both methods The instruments must be placed appropriately i...
Страница 26: ...ults However they can be changed in relation to the quantity of detergent The remaining 10 positions from 21 to 30 are empty and can be used by the customer to create his own programs These new progra...
Страница 27: ...r without additives to eliminate coarse dirt and foam substances Hot alkaline wash effective action that detaches the pollutants from the walls and solubilizes them this phase is usually performed at...
Страница 28: ...created as these areas obstruct cleaning of other instruments instruments with cavities flexible tubes respiration systems etc must have the possibility of being completely rinsed even internally The...
Страница 29: ...m washing and disinfecting results depending on the case in question Here are the products for which Smeg guarantees the envisaged washing results alkaline detergents Smeg s DETERLIQUID D and D2 acid...
Страница 30: ...contaminated garments Contact with the skin Immediately wash the affected area with plenty of water if the product splashes on to the skin Contact with the eyes If the product splashes into the eyes...
Страница 31: ...or 10 thus with a 90 lethality degree at a particular temperature value z can be expressed as the temperature increase in K degrees required to reduce D in boldface by a factor 10 In view of this A0 s...
Страница 32: ...Manuale GW3060 User Versione 22 10 08 32 time in seconds for which the disinfection temperature must be maintained T disinfection temperature in C...
Страница 33: ...RGENT NEUTRALIZATION WITH ACID DETERGENT RINSE IN DEMINERALIZED WATER RINSE IN DEMINERALIZED WATER AT 75 C 30 5 GLASSWARE STANDARD WASH WASH AT 80 WITH ALKALINE DETERGENT NEUTRALIZATION WITH ACID DETE...
Страница 34: ...ENT RINSE IN DEMINERALIZED WATER RINSE IN DEMINERALIZED WATER AT 75 C 40 11 THERMAL DISINFECTION 95 C 10 THERMAL DISINFECTION AT 95 FOR 10 MIN WITH ALKALINE DETERGENT NEUTRALIZATION WITH ACID DETERGEN...
Страница 35: ...ETERGENT CAUSTIC SODA WASH AT 95 C FOR 10 MIN WITH ALKALINE DETERGENT CAUSTIC SODA ANTIFOAM NEUTRALIZATION WITH ACID DETERGENT RINSE RINSE IN DEMINERALIZED WATER RINSE IN DEMINERALIZED WATER AT 75 C 6...
Страница 36: ...se electric power supply Cold water supplied at 20 C 3 bar Programs 1 and 2 are actually not washing programs but simple prewashes lasting 5 minutes They are useful if the appliance is partially fille...
Страница 37: ...ome the situation By and large an alarm indicates that the machine is operating in a faulty way and needs to be repaired by a technician Sometimes however the alarm may be caused by a temporary situat...
Страница 38: ...tc 14 COLD WATER PRESSURE Check the water supply cock open closed water pressure connection pipe etc 15 WARM WATER PRESSURE Check the water supply cock open closed water pressure connection pipe etc 1...
Страница 39: ...Repeat the cycle Call the Technical Assistance Service if the fault persists 34 CONDENSER DRAINAGE FAILED Make sure that the drain pipe is positioned as indicated in the manual 35 CONDENSER LEVEL SWIT...
Страница 40: ...the bottom of the drawer see 17 1 and repeat the cycle If the fault persists call the Technical Assistance Service 62 HEATING THERMOSTAT ON Press the 1st button located on the bottom of the bottom dra...
Страница 41: ...RATURE TA1 Repeat the cycle Call the Technical Assistance Service if the fault persists 86 PUMP P1 BLOCKED Repeat the cycle Call the Technical Assistance Service if the fault persists 87 PUMP P2 BLOCK...
Страница 42: ...in order to clean the nozzles and prevent clogging Periodically remove the spraying arms after having unscrewed the knurled nuts wash them carefully fit them back in their housings and fully tighten...