Instructions for the Installer

9.2

Room ventilation

The appliance may only be installed in a permanently ventilated room as
specified by the relevant regulations. The air flow into the room where the
appliance is installed must be sufficient for proper gas combustion and
room ventilation. The air intakes, protected by gratings, must be of
suitable size (see relevant regulations) and located so that they cannot be
even partially obstructed. The kitchen must be kept properly ventilated to
disperse the heat and humidity produced by cooking processes: in
particular, a window should be opened or the speed of any fans increased
after prolonged use.

9.3

Combustion gas discharge 

Combustion gases must be discharged by means of hoods connected to a
flue with reliable natural draught, or a fan extraction system. An effective
extraction system requires careful design by an authorised specialist, and
must comply with the regulation distances and positions. After installation,
the engineer must issue a certificate of compliance.

Содержание GD100XG

Страница 1: ...intended for the qualified engineer who is to install commission and test the appliance 1 PRECAUTIONS FOR USE 22 2 DISPOSAL INSTRUCTIONS OUR ENVIRONMENT POLICY 22 3 SAFETY PRECAUTIONS 24 4 GETTING TO...

Страница 2: ...ONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL LIABILITY FOR USES OTHER THAN THOSE STATED ABOVE NEVER USE THIS APPLIANCE FOR HEATING ROOMS NEVER USE PACKAGING RESIDUES UNATTENDED IN THE HOME SEPARAT...

Страница 3: ...s for the addresses of collection recycling and disposal facilities Never leave all or part of the packaging lying around Packaging parts and especially plastic bags may represent a suffocation hazard...

Страница 4: ...NECT THE PLUG BY PULLING ON THE POWER SUPPLY LEAD THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH ELECTRICAL SYSTEM SAFETY REGULATIONS IMMEDIATELY AFTER INSTALLATION CARRY OUT A QUICK TEST...

Страница 5: ...als by type and consign them to the nearest separate disposal centre The inside of the appliance should be cleaned to remove all manufacturing residues For further information see point 7 CLEANING AND...

Страница 6: ...until the burner lights If it does not light within the first 15 seconds turn the knob to 0 and wait at least 60 seconds before trying to light the burner again On models equipped with valves once th...

Страница 7: ...r enough to prevent the liquid from boiling over When cooking to prevent burns or damage to the hob all pans or griddle plates must be placed inside the perimeter of the hob Take the greatest care whe...

Страница 8: ...2 Food stains or spills Never use metal scouring pads or sharp scrapers which will damage the surface Use ordinary non abrasive products for steel with the aid of wooden or plastic utensils if necessa...

Страница 9: ...0 mm from the rear edge This appliance may be installed against walls higher than the worktop surface provided the distance X shown here is maintained in order to prevent damage due to overheating Mak...

Страница 10: ...nce the appliance has been installed This appliance may be installed against walls higher than the worktop surface provided the distance of 100 mm shown in the figure is maintained in order to prevent...

Страница 11: ...7 detail A Before fitting the hob apply the adhesive sponge strip supplied B along the entire surface of the cut fig 7 Now place the 12 brackets supplied to secure the top to the supporting structure...

Страница 12: ...to be installed to a cabinet of 20mm to 30mm thickness Detail C or 30mm to 50mm thickness Detail B the brackets A mount to different holes in the hob s casing see fig 7 6 7 Important When fixing this...

Страница 13: ...ily accessible position close to the appliance itself If a socket and plug connection is used check that they are of the same type Do not use reducers adapters or junctions since they may cause overhe...

Страница 14: ...with other types of gas see point 10 ADAPTING TO DIFFERENT TYPES OF GAS The gas intake connection has an external gas thread ISO 228 1 Connection with copper pipe The connection to the gas supply main...

Страница 15: ...t be even partially obstructed The kitchen must be kept properly ventilated to disperse the heat and humidity produced by cooking processes in particular a window should be opened or the speed of any...

Страница 16: ...other types of gas the burner nozzles have to be changed and the gas taps adjusted to set the minimum flame To replace the nozzles proceed as described below 10 1 Changing the hob nozzles 1 Remove the...

Страница 17: ...3 2 3 75 45 42 800 167 164 Fish pan 4 1 9 68 45 42 900 138 136 diameters marked and must be fitted respectively on valves marked and shown in point 11 1 Adjusting the minimum setting for natural gas B...

Страница 18: ...or screw inside or beside the tap rod depending on the model until an even minimum flame is obtained Put the knob back in place and check the stability of the burner flame the flame must not go out wh...