Installation
39
EN
Burner and nozzle characteristics table
Overall dimensions
Location of gas (G) and electrical (E)
connection points.
5.4 Positioning
1 ULPG 2.75 kPa
AUX
SR
UR-3c
Nominal gas consumption (MJ/h)
3.9
6.3
15.0
Injector (1/100 mm)
54
68
105
2 NG 1.0 kPA
AUX
SR
UR-3c
Nominal gas consumption (MJ/h)
3.9
7.5
15.0
Injector (1/100 mm)
90
120
175
A
124 mm
B
32 mm
C
42 mm
D
628 mm
F
min. 105 mm - Max. 160 mm
H
770 mm
L
598 mm
Heavy appliance
Danger of crush injuries
• Place the appliance into the piece of
furniture with the aid of a second person.
Pressure on the open door
Risk of damages to the appliance
• When positioning the appliance during
installation, do not use the door handle
to lift up or move this appliance.
• Never use the oven door to lever the
appliance into place when fitting.
• Avoid exerting too much pressure on the
oven door when open.
Heat production during appliance
operation
Risk of fire
• Veneers, adhesives or plastic coatings
on adjacent furniture should be
temperature-resistant (no less than
90°C).