Instructions for the installer
13
4.
FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the
burner caps and the grids.
4.1
Adjustment of the hob burner minimum level for natural gas
4.2
Adjustment of the hob burner minimum level for LPG
(propane)
To regulate the minimum for LPG (propane), completely tighten
(clockwise) the screw inside or next to the gas tap pin (depending on the
model).
4.3
Arrangement of the burners on the hob
Burners
1
Auxiliary
2
Semi rapid
4
Wok
Light the burner and turn it to the minimum
position . Extract the gas tap knob and
turn the adjustment screw at the side of the
tap rod until the correct minimum flame is
achieved. Refit the knob and verify that the
burner flame is stable (turning the knob
rapidly from the maximum to the minimum
position the flame must not go out). Repeat
the operation on all the gas taps.