Instructions for the installer
87
12.2 Cable replacement
• Unscrew the securing screws
from the cover terminal;
• Remove the tabs
from the
cover terminals;
• Loosen the cable securing screws
from the lower part of the rear of the
oven ;
• Loosen the terminal cables;
• Replace the cable securing it to the
terminal as described on the label
on the rear of the appliance;
• When the cable has been replaced
repeat the steps described above in
reverse.
The cable cross-section must be no less than 1.5 mm².
Make sure that the cables follow the best route in order to avoid any contact with
the oven.
WARNING:
The tightening torque of the screws of the terminal supply wires
must be
1.5 - 2 Nm.
3
1
2