CWH
510
D
6
2 TECHNICAL
DATA
CWH
510
D
Supply
voltage
V
400V
3N
~
Supply
voltage
V
Frequency
Hz
50
Max.
power
absorption
at
400V
3N
~
kW
5.2
Max.
power
absorption
at
230V
1N
~
kW
3.7
Boiler
heating
element
power
at
400V
3N
~
kW
4.5
Boiler
heating
element
power
at
230V
1N
~
kW
3
Tank
heating
element
power
kW
0,8
Water
intake
pressure
kPa
(bar)
200
‐
600
(2
÷
6)
Water
intake
temperature
°C
15°C
–
60°C
Intake
water
hardness
(
models
with
softener)
°f
15°f
‐
60°f
Rinse
cycle
water
consumption
l
3.2
Boiler
capacity
l
6
Tank
capacity
l
11
Standard
cycle
duration
with
intake
water
at
50°C
s
90/120/180
Noise
level
dB(A)
<
70
Degree
of
protection
IPX
4
Net
weight
Kg
79
Power
supply
cable
type
◄
HAR
►
H07RN
‐
F
Fuse
A
4
CWH
510
D
400V
3N
~
230V
1N
~
C
S
C
C
=
Power
Supply
Cable
S
=
master
switch
3.7kW
‐‐‐‐
‐‐‐‐
3.7kW
‐‐‐‐
5.2kW
5x2.5
16°
3P+N
5.2kW
5x2.5
Содержание CWH510D
Страница 1: ...PROFESSIONAL DISHWASHER ...
Страница 12: ... CWH 510 D 12 Figure 1 Appliance three phase electrical system diagram ...