CWG410
‐
16
6.4
Modifiable
parameters
This
table
lists
the
model
choice
or
cycle
and
temperature
option
parameters.
F/
M
ID
Description
Default
Min.
Max
Notes
M
P0
Appliance
Type
1
1
4
Construction
version
Do
not
modify
F
P1
Appliance
Model
Do
not
modify
M
P2
Boiler
temperature
80C
60C
90C
Step
1
degree
WARNING:
The
actual
boiler
temperature
depends
on
whether
the
connection
is
single
‐
phase
or
three
‐
phase.
With
three
‐
phase
connection,
do
not
set
more
than
85°
M
P3
Tank
temperature
58C
40C
65C
Step
1
degree
M
P4
Thermostop
option
0
0
1
0=off
1=on
M
P5
Soft
Start
option
1
0
1
0=off
1=on
M
P6
Boiler
temperature
offset
0
‐
20
+20
Real=mOffset
M
P7
Tank
temperature
offset
4
‐
20
+20
Real=mOffset
M
P8
Real
temperature
display
1
0
1
0=
filtered,
1=
real
F
P9
Tank
probe
type
1
0
1
Do
not
modify
Note
for
P6
and
P7:
negative
numbers
are
indicated
by
illumination
of
both
decimal
points
(e.g.:
‐
12
“1.2.”)
“1.2.”)
6.5
Alarm
trigger
time
thresholds
This
table
lists
all
the
safety
device
trigger
time
thresholds.
F/
M
ID
Description
Default
Min
.
Max
Notes
F
A0
F
A1
Boiler
max.
heating
time
20
min
5
60
Step
=
1
min
F
A2
Tank
max.
heating
time
50
min
5
60
Not
active
with
PL
ON
F
A3
Maximum
water
intake
time
5
min
1
20
Step
=
1
min
F
A4
Maximum
emptying
wait
time
1
min
1
2
Step
=
1
min