13
6.1.11 Setting the Model (for After-Sales Service only)
Modify by pressing .
6.2 Starting the peristaltic pumps – rapid filling of detergent and rinse aid delivery
circuit.
Perform after the parameter modification procedure explained in the previous point.
Indicator lights as follows: off; green; orange;
flashing.
With the dishwasher powered up, access “programming mode” by pressing the
on/off button for a few seconds; at the “beep”, release the button and press it
again
quickly within 0.5 seconds
.
The peristaltic pumps continue to operate until the same buttons are pressed
again. The rinse aid and detergent symbol lights remain on as long as work is
in progress; bear in mind that the rinse aid peristaltic pump fills the circuit in
about 7 minutes, while for the detergent it only takes 2 minutes.
7 MALFUNCTIONS SHOWN ON THE DISPLAY
The dishwasher is able to identify a number of malfunctions and show them on the display.
If the problem persists after the dishwasher has been switched off and back on, proceed as described below:
Err01
The anti-flooding system has been activated
(for the relevant models only).
Large water leak : check the origin of the problem.
Err04
Tank temperature probe malfunction
Tank temperature probe disconnected or not working
Err05
Tank water filling malfunction
Check dynamic pressure in intake system, inspect water
intake filter and clean if necessary.
If the problem persists:
- tank pressure switch has failed (continuous empty
reading)
- leak from pipe connected to air trap
- valve vent exhaust pipe blocked
Err06
Water pump-out malfunction
Inspect the filters for dirt and that the drain hose is not
blocked, bent or crushed.
Check that the drain pump is not blocked by dirt by
removing the insert on the sump (from inside the tank)
If the problem persists:
‐
with the tank empty: tank pressure switch defect
(the contact is locked on full)
‐
with tank full: drain pump has failed
Err09
Tank water level too high
- with tank full:
see above (water pump-out malfunction)
- with tank empty:
safety pressure defect (the contact
is locked on full)
Err23
Boiler heating malfunction (does not heat
up)
-circuit board relay failure,
- contactor failure.
- boiler safety thermostat failure,
- boiler temperature probe faulty or incorrectly positioned