Installation
138
Burner and nozzle characteristics tables
1 Natural gas G20 – 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.2
Nozzle diameter (1/100 mm)
72
97
120
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(H9)
(F3)
Reduced flow rate (W)
400
500
800
1200
2 Natural gas G20 – 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.1
1.8
2.9
4.2
Nozzle diameter (1/100 mm)
72
94
110
145
Pre-chamber (printed on nozzle)
(X)
(Z)
(H8)
(H3)
Reduced flow rate (W)
400
500
800
1200
3 Natural gas G25.1 – 25 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.1
Nozzle diameter (1/100 mm)
77
100
134
152
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
4 Natural gas G25 – 20 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.8
3.0
4.0
Nozzle diameter (1/100 mm)
77
100
134
165
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
(H3)
Reduced flow rate (W)
400
500
800
1200
5 Natural gas G2.350 – 13 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.75
3.0
3.8
Nozzle diameter (1/100 mm)
94
120
165
190
Pre-chamber (printed on nozzle)
(Y)
(Y)
(F3)
(F3)
Reduced flow rate (W)
400
500
800
1200
6 Liquid gas – G30/G31 30-37 mbar
AUX
SR
R
UR2
Rated heating capacity (kW)
1.0
1.75
3.0
4.0
Nozzle diameter (1/100 mm)
50
65
85
100
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1300
Rated flow rate G30 (g/h)
73
127
218
291
Rated flow rate G31 (g/h)
71
125
214
286
Содержание CPF9GMAN