
Installation
21
EN
The range and its individual shut-off valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures greater than
½ PSIG (3.5 kPa).
Testing below ½ PSIG (3.5 kPa) with a
water column pressure of 14” (35.6 cm)
(gauge).
The range must be isolated from the gas
supply piping system by closing the
respective manual shut-off valve during any
pressure testing of the gas supply piping
system at test pressures equal to or less than
½ PSIG (3.5 kPa).
Lubricating the surface burner gas valves
Over time, the surface burner gas valves
may become stiff or jam. Clean them
internally and relubricate. This operation
must be carried out by a qualified
technician.
Assembling the backguard
The backguard must always be positioned
and secured correctly on the appliance.
1. Position the backguard above the top,
taking care to align the holes.
2. Secure the backguard to the top by
tightening screws.
3. For the two outermost screws, also
tighten the supplied spacers, as per
figure.
The backguard provided is an
integral part of the product; it must
be fastened to the appliance prior
to installation.