Installation
37
EN
The appliance can work in the following
modes:
•
220-240 V 1N
~
3 x 6 mm²
three-core
cable.
•
380-415 V 2N
~
4 x 4mm²
four-core cable.
•
380-415 V 3N
~
5 x 2.5 mm²
five-core cable.
Fixed connection
Fit the power line with an omnipolar circuit
breaker in compliance with installation
regulations.
The circuit breaker should be located near
the appliance and in an easily reachable
position.
Connection with plug and socket
Make sure that the plug and socket are of
the same type.
Avoid using adapters, gang sockets or
extensions as these could cause
overheating and a risk of burns.
5.3 For the installer
• The plug must remain accessible after the
installation is complete. Do not kink or
trap the mains connection cable.
• The appliance must be fitted according
to the installation diagrams.
• Do not attempt to turn or stress the
threaded elbow on the manifold. You risk
damage to this part of the appliance
which may void the manufacturer’s
warranty.
• In case the appliance fails to operate
correctly after all checks have been
carried out, refer to the Authorised
Assistance Centre in your area.
• When satisfied with the appliance,
please instruct the user on the correct
method of operation.
The values indicated above refer
to the cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).
Содержание Classica SCD90CMX9
Страница 36: ......