Installation
98
The nozzles not provided are available at Authorised Service Centres.
7 Liquid gas – G30/31 – 30/37 mbar
AUX
SR
R
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.0
1.8
3.0
0.9
3.8
Nozzle diameter (1/100 mm)
50
65
85
44
96
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
400
500
800
400
1300
Rated flow rate G30 (g/h)
73
131
218
65
298
Rated flow rate G31 (g/h)
71
129
214
64
293
8 LPG G30/31 – 37 mbar
AUX
SR
R
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.1
1.9
3.0
0.8
3.9
Nozzle diameter (1/100 mm)
50
65
81
42
93
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
450
550
900
450
1500
Rated flow rate G30 (g/h)
80
138
218
58
284
Rated flow rate G31 (g/h)
79
136
214
57
279
9 LPG G30/31 – 50 mbar
AUX
SR
R
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.0
1.8
3.0
1.0
3.8
Nozzle diameter (1/100 mm)
43
58
74
43
75
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(H2)
(S1)
Reduced flow rate (W)
400
500
1000
400
1500
Rated flow rate G30 (g/h)
73
131
218
73
276
Rated flow rate G31 (g/h)
71
129
214
71
271
10 Town gas G110 – 8 mbar
AUX
SR
R
UR2 int.
UR2 ext.
Rated heating capacity (kW)
1.0
1.8
2.9
1.0
3.2
Nozzle diameter (1/100 mm)
145
185
260
145
300
Pre-chamber (printed on nozzle)
/8
/2
/3
0040
0190
Reduced flow rate (W)
400
500
800
400
1000