background image

 

Instructions for the installer 

 

 

3.

 

GAS CONNECTION 

This appliance is suitable for installation with 
Natural Gas or LPG (propane). Refer to page 12 
for the relevant burner pressure and appropriate 
injector sizes. When the appliance is to be 
connected to Natural Gas then the pressure 
regulator supplied must be fitted to the gas inlet. A 
test point (for checking the gas pressure) is 
supplied either with the regulator or as a separate 
fitting in the case of LPG (propane) appliances. 
Connection of the appliance to the gas supply 
must be in accordance with the requirements of 
AS5601. A ½” BSP connector at the inlet is 
recommended and the gas supply line to the 
appliance must be of adequate length to allow 
sufficient withdrawal of appliance for service or 
disconnection and be: 

1.

 

annealed copper pipe or; 

2.

 

flexible hose according to AS/NZ1869 & be at 
least Class “B”, 10 mm diameter. 

 

The appliance must be installed with provision to allow the gas to be 
turned off and disconnected for servicing and removal of the appliance 
as required from the gas supply. 
Before the appliance is operated make certain all relevant parts are 
placed in the correct position. 
When the installation is completed the installation connections of 
appliance will require to be leak tested, the burner operating pressure 
and flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To check the operating pressure of the appliance it is recommended at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G. The regulator supplied must be fitted to the ½ BSP thread at the 
rear of the appliance. An approved manual shut-off valve must be 
installed. The N.G. regulator must be checked and adjusted to 1.0kPa 
after installation. 

 

L.P.G. Can be connected to the inlet fitting directly. 
The pressure must be checked to ensure it is 
operating at 2.75kPa. A separate test point fitting 
must be installed between the piping & the appliance 
for the pressure to be checked to ensure it is 
operating at 2.75kPa. 

11 

Содержание CIR60XS3

Страница 1: ...NCE ___________________________ 21 9 PROBLEMS AND CAUSES ________________________________ 24 Thank you for choosing our product We advise you to read this manual carefully It contains all necessary in...

Страница 2: ...DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS...

Страница 3: ...NLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION THIS APPLIANCE IS DESIGNED FOR COOKING FOOD AND IT...

Страница 4: ...can therefore be mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from...

Страница 5: ...s to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical servic...

Страница 6: ...hall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or for an overhead exhaust fan 750 mm Any other downward facing combustible surface...

Страница 7: ...phery of the nearest burner to a horizontal combustible surface is less than 200 mm then E shall be 10 mm or more or the horizontal surface shall be above the trivet See insets above NOTES 1 Requireme...

Страница 8: ...that they cannot be obstructed indoors or outdoors and should preferably be close to the floor on the side opposite to the combustion gas discharge point If it is not possible to make the openings in...

Страница 9: ...to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are place...

Страница 10: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind...

Страница 11: ...laced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the gr...

Страница 12: ...gas to use The screwing torque of the nozzle should never exceed 3 Nm Reposition support B so that nozzle C is covered perfectly Place the burner on its support and ignite it Move the Venturi tube D t...

Страница 13: ...k back with this type of gas after it has been adjusted for LPG perform the same operations described in paragraph 6 2 Regulation for LPG but refer to the following table for the proper injectors NG 1...

Страница 14: ...he model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation o...

Страница 15: ...on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Rapid 4 Rapid 5 WOK 6 4 Lubrification of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be cleaned inside and r...

Страница 16: ...orresponding burner is indicated The device is fit with electronic ignition Simply press and simultaneously turn the knob counter clockwise on the low point flame symbol until the burner is ignited Co...

Страница 17: ...s or griddles must be positioned within the cooking hob perimeter and must be a minimum distance of 3 4 cm from the knobs 7 3 Diameter of containers Burner min and max in cm 1 Auxiliary 12 14 2 Semi r...

Страница 18: ...n switching on the electric element for the first time or if the electric element has not been used for a long time to remove any humidity from the insulating material it should be dried out by placin...

Страница 19: ...e surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly...

Страница 20: ...ed for ease of cleaning Wash them in warm water using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out 8 2 1 Ignition plugs and sa...

Страница 21: ...s connection the gas connection must be checked periodically at least every 2 years Each time the cooker is moved the connection may be stressed test it for leakages using special sprays or a solution...

Страница 22: ...ts on the bottom of the pans Defect of comburent air or incorrect injectors Burner dirty or flame ports obstructed Clean the burner Call Service Center if the problem remains The flame is very short a...

Страница 23: ......

Страница 24: ...914773400 B...

Отзывы: