Smeg CIR574XS3 Скачать руководство пользователя страница 19

 

 

Instructions for the user

 

 

 

21 

 

8.3 Preventive maintenance 

 

This appliance does not need any special maintenance. However, a few 
simple  operations  have  to  be  carried  out  periodically  to  prevent 
malfunctioning: 

 

 

 

Burners:  the  burners  must  be  cleaned  after  every  use  to  ensure  correct 
combustion; make sure that all the openings and flame ports are clean and 
free of obstacles, and that the burners rest firmly on their supports. 

 

 

Gas connection: the gas connection must be checked periodically (at least 
every  2  years).  Each  time  the  cooker  is  moved  the  connection  may  be 
stressed: test it for leakages using special sprays or a solution of soap and 
water. 

 

 

Flexible  pipes:  if  a  flexible  pipe  is  used,  it  must  be  inspected  periodically 
(once  a  year)  for  leakages:  if  the  surface  of  the  pipe  appears  rigid  and 
cracked,  disconnect  immediately  the  cooker  from  the  gas  supply  and 
replace the pipe with a new one. 

 

 

Valves: if the gas valves get stuck or hard to turn, they need to be cleaned 
and re-greased; this operation must be carried out by an authorised person. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание CIR574XS3

Страница 1: ...AINTENANCE____________________________ 20 9 PROBLEMS AND CAUSES_________________________________ 22 Thank you for choosing our product We advise you to read this manual carefully It contains all neces...

Страница 2: ...SIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE...

Страница 3: ...USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN...

Страница 4: ...relation to fire hazards and can therefore be mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figur...

Страница 5: ...Instructions for the installer 7 Overall dimensions location of gas and electrical connection points all measures in mm 30 CM HOB 70 CM HOB A 60 120 B 90 90 C 30 30 D 90 70...

Страница 6: ...ver in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or for an overhead exhaust fan 750 mm Any other downward facing com...

Страница 7: ...rt of the appliance where cooking normally takes place and does not include those parts of the appliance containing control knobs 3 For definition of hob see Clause 1 4 64 4 For definition of trivet s...

Страница 8: ...propane Refer to page 12 for the relevant burner pressure and appropriate injector sizes When the appliance is to be connected to Natural Gas then the pressure regulator supplied must be fitted to th...

Страница 9: ...calls do not cover these adjustments To check the operating pressure of the appliance it is recommended at least 2 large size burners are used Ensure appliance is secured to wall when installation is...

Страница 10: ...ccessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 0 mm 2 3 x 1 0 cable keeping in mind th...

Страница 11: ...laced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the gr...

Страница 12: ...ld never exceed 3 Nm Reposition support B so that nozzle C is covered perfectly Place the burner on its support and ignite it Move the Venturi tube D to regulate the air flow until the flame is stable...

Страница 13: ...55 Wok 4 15 0 1 70 Wok dual control 5 18 8 Outer 14 0 1 65 Inner 4 8 0 98 For burner reference numbers see page 16 6 FINAL OPERATIONS Having carried out the above adjustments reassemble the appliance...

Страница 14: ...he hob Burners 1 Auxiliary 2 Semi rapid 3 6 Rapid 4 Wok 5 Wok dual control 6 3 Lubrication of gas taps With time it may happen that the gas taps get blocked and hard to turn Clean them inside and re g...

Страница 15: ...responding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use both burner...

Страница 16: ...accidentally goes out turn off the control knob and wait at least 1 minute before trying to re light the burner 7 3 Diameter of containers Burner min and max in cm 1 Auxiliary 12 14 2 Semi rapid 16 2...

Страница 17: ...When switching on the electric element for the first time or if the electric element has not been used for a long time to remove any humidity from the insulating material it should be dried out by pl...

Страница 18: ...ins or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots or residuals with non scratch sponges or if need be with wo...

Страница 19: ...Gas connection the gas connection must be checked periodically at least every 2 years Each time the cooker is moved the connection may be stressed test it for leakages using special sprays or a solut...

Страница 20: ...he bottom of the pans Defect of comburent air or incorrect injectors Burner dirty or flame ports obstructed Clean the burner Call Service Center if the problem remains The flame is very short and nois...

Отзывы: