can be seen when the motor is off and for about 30 seconds. To reset the hour counter, keep the button pressed
for 2 seconds while the alarm can be seen.
Controls shown in Fig. 12:
Button A: turns the lights on/off; every 30 hours of operation the corresponding
pilot lamp (S) comes on to indicate that the grease filters must be cleaned; every 120 hours of operation the
corresponding pilot lamp (S) flashes to indicate that the grease filters must be cleaned and the charcoal filter
replaced. To restart the hour counter (RESET), hold the button A pressed down for about 1” (while the pilot lamp
S is on).
Button B: drives the motor in first speed (the corresponding pilot lamp comes on); when holding it down for about
1”, the motor cuts out; when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated
and thus the motor stops after 5’ (the pilot lamp flashes). Button C: drives the motor in second speed (the
corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the
TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button D: drives the motor in third
speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is
on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button E: drives the motor
in fourth speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot
lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes).
Controls shown in Fig. 13:
Button A = light switch. Button B = motor ON/OFF switch – speed I.
Button C = speed II switch; pressed a second time, the timer is activated and the motor turns off after 10’: the
relevant LED flashes continuously. Button D = speed III switch; the timer acts as for switch C. Button E =
speed IV switch; the timer acts as for switch C.
When all the LEDs flash together, this means the grease filters need cleaning (about every 30 hours of operation).
To start the hour count again, press key C twice (or else keys D or E).
Pay special attention to the
grease filters
: if the model purchased has the controls shown in Figure 11:
the grease filters must be cleaned approximately once every 30 hours of operation (when the central segment
on the display goes on or starts blinking). Wash out the filter using a neutral soap. Once the cleaned filters are
reinstalled, keep button R (Reset) pressed for two seconds to reset the counter. If the model purchased has the
controls shown in Figure 12: the grease filters must be cleaned approximately once every 30 hours of operation
(when the light button lamp comes on) - Fig. 12S). Wash out the filter using a neutral soap. Once the cleaned
filters are reinstalled, to reset the counter hold the light button pressed down for about 1” (Fig.12A) while the
corresponding pilot lamp (S) is on. If the model purchased has the controls shown in Figure 13: the grease filters
must be cleaned approximately once every 30 hours of operation (when all the LEDs flash together). Wash out
the filter using a neutral soap. Once the cleaned filters are reinstalled, press key C twice (or else keys D or
E) to reset the counter
Removing the grease filters
: Remove the grease filters by moving fastener B and turning the filter outwards
(Fig.5).
Replacing the charcoal filters:
for filtering hoods, the charcoal filters must be replaced. If the model purchased
has the controls shown in Figure 11, the charcoal filters must be replaced whenever the central segment of the
display starts blinking (i.e. every 120 hours of operation). If the model purchased has the controls shown in
Figure12, the charcoal filters must be replaced each time the light button (Fig.12S) lamp flashes (i.e. every 120
hours of operation). If the model purchased has the controls shown in Figure 13, the charcoal filters must be
replaced according to use: on the average once every 6 months.
Removing the charcoal filters
: before removing the charcoal filters, the grease filters will have to be removed
by moving catch B and turning the filter outwards (Fig. 5). Then remove the charcoal filters by turning until they
are released from the pins (Fig. 14).
Lighting
: to remove the halogen lamps, turn the locknut counter-clockwise (Fig. 15). Replace with the same
type of lamp.
CAUTION: Do not handle glass bulb with bare hands.