Instructions for the Installer
9
2.4.4
Bottled gas connection
Use a pressure regulator complaint with the relevant standards and make the connection to the gas
cylinder in accordance with the relevant regulations.
Make sure that the gas supply pressure is as stated in the table in point "3.2/3.3 Burner and Nozzle
Data Tables".
Screw the small hose connector
F
onto the large hose connector
A
and
connect the resulting unit to the gas union
B
(or use the hose connector
G
for connection straight to the gas union
B
) and fit the seal
C
. Fit the
ends of the rubber hose
H
onto the hose connector
A+F
(or
G
) and to
the outlet union of the pressure reducer on the gas cylinder. Fix the end
of the hose
H
to the hose connector
A+F
(or
G
) using the regulation
hose clamp
I .
The hose connector
G
shown is not supplied with the appliance. Use only hose connectors
compliant with the relevant regulations.
2.4.5
Connection with steel hose (for all types of gas)
This type of connection can be made on both built-in and free-standing
appliances. Use only regulation steel hoses no more than 2 metres
long. Screw the end of the hose
L
, fitting the seal
C
, onto the gas union
B
with external ½" gas thread (ISO 228-1).
When installation is complete, check for any leaks with a soapy
solution, never with a naked light.