WARNING!

 

Read the instructions carefully before installing and/or using the hood.

 

Before connecting, make sure that the mains voltage corresponds to the voltage on
the rating plate inside the hood. (see fig. 7)

 

Once you remove the appliance from its packaging make sure it is intact. If the
product is damaged, do not use it and contact the Smeg assistance network.

 

It is recommended that a qualified technician performs installation and adjustment
operations

.

 

The minimum distance between the cooker and the lower part of the hood must be
750mm for gas cookers and 650 mm for electric cookers.

 

Before carrying out any kind of maintenance or cleaning, disconnect the hood from
the mains supply.

 

Inspect and clean the filters thoroughly and in accordance with the intervals
suggested by the manufacturer.

 

Do not cook or fry in a way that could result in flames being sucked into the hood and
causing a fire.

 

The hood surface can be cleaned with a damp cloth and a non-bleach liquid
detergent.

 

Make sure the room is properly ventilated when using the hood and other gas
appliances at the same time.

 

Comply with the regulations on air discharge when operating the hood.

 

The extracted air must not  be routed into a duct used to discharge fumes of gas-
operated appliances.

 

This appliance must not be used by children without an adult supervision
and disabled people may require assistance.

 

THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED

.

OPERATION

This appliance has been designed to work as a 

DUCTING 

hood (evacuation of the

air) or 

RECYCLING 

hood

 

(recycling of the filtered air).

 

DUCTED MODE:

 In order to use the hood in the ducted mode, connect the motor

intake, by means of a suitable ducting hose not less than 120mm diameter, directly to
the external fumes outlet.

Note:

 Remove any carbon filters.

 

RECIRCULATION MODE:

 If it is not possible to discharge fumes outside, the hood

can be used to filter and recycle the air. This way, air and fumes are filtered by the
anti-odour carbon filters and recirculated through the aerating grids on the sides of
chimney.

EN

01

INSTALLATION INSTRUCTIONS:

The hood is supplied with all the necessary
accessories for installation

.  The minimum distance

between the cooker and the lower part of the hood
must be 750 mm for gas cookers and 650 mm for
electric cookers 

(Fig. 1). The hood is supplied with a

motor intake (Fig 2). If it has not been assembled by
the manufacturer, you can assemble it using the
supplied screws (for type 1) or pushing (for type 2)

If the motor intake is equipped with a non-return
valve, make sure it opens and closes perfectly.

The following instructions will assist installation:
a)  The hood should be centred with respect to the

cooker.

b)  The hood is supplied with two supports/hooks (a)

(Fig 3) or bracket (b) that need to be fixed to the
wall by means of wall anchors . The L1 holes for
these supports are on the back of the hood (fig.
4)

c)  Remove the anti-grease filters, put the hood on

the wall and mark the position of the holes for the
supports/hooks.

d)  Drill the two previously marked holes after

removing the hood from the wall.

e)  Fix the two supports/hooks to the wall.
f) 

Mark the L2 holes on the wall to fix the hood
safely. (fig. 4) Drill and put the anchors in the
holes.

g)  Hang the hood on to the supports/hooks (fig. 5)

and level by means of the adjusting screw
(

fig.3

).

h)  Fix the hood safe by tightening both wall anchors.

Ducted mode 

or 

Recirculation mode 

installation

:

Ducted mode:

In the ducted mode, connect the motor outlet to the
fumes outlet duct not less than 120mm diameter.

Warning: if the hood is equipped with an active
carbon filter, it must be removed (see page 7)

EN

02

Fig.2

Hood levelling screw

Fig.3

Type 1

Type 2

Fig.1

(a)

(b)

Содержание CA12SHRPX

Страница 1: ...h and a non bleach liquid detergent Make sure the room is properly ventilated when using the hood and other gas appliances at the same time Comply with the regulations on air discharge when operating...

Страница 2: ...fixed to the wall by means of wall anchors The L1 holes for these supports are on the back of the hood fig 4 c Remove the anti grease filters put the hood on the wall and mark the position of the hole...

Страница 3: ...group back in place and fix it to the hood with the Z screws and to the chimney bracket with the L screws as shown in figure 6 ELECTRICAL CONNECTION It is recommended that all electrical connection o...

Страница 4: ...ours have disappeared To start the hood identify your type of control panel and follow the instructions SLIDER Key A to turn on off the hood s light Four position Cursor B 0 Off 1 2 3 On Speed adjustm...

Страница 5: ...ers cleaning memory It is recommended that grease filters are cleaned every 100h and active carbon filters are replaced every 200h CLEANING AND MAINTENANCE Before performing any cleaning and or mainte...

Страница 6: ...hed therefore it is recommended they are replaced at least once every six months or more frequently in the case of a heavy use of the appliance Before starting make sure the hood is disconnected from...

Страница 7: ...b Halogen lamps G4 20W 12V lamps To replace the lamp use a screwdriver to remove the glass supporting ring Then remove the old lamp and insert the new one Put the glass back securing it with the ring...

Страница 8: ...eg Warranty Booklet for complete information about the warranty N B bulbs and filters are not covered by your warranty In the case of failure please call Customer Service 0870 9909907 and provide the...

Отзывы: