Installation
83
EN
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Natural Gas G20 – 20 mbar
AUX
SR
UR
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
72
97
135
Pre-chamber (printed on nozzle)
(X)
(Z)
(K)
Reduced flow rate (W)
400
500
1600
Natural Gas
G25 - 25 mbar / G25.3 - 25 mbar
AUX
SR
URP
Rated heating capacity (kW)
1.05
1.8
3.9
Nozzle diameter (1/100 mm)
72
94
145
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F3)
Reduced flow rate (W)
400
500
1600
LPG
G30/31 - 30/30 mbar
AUX
SR
URP
Rated heating capacity (kW)
1.0
1.8
3.9
Nozzle diameter (1/100 mm)
50
65
100
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
1600
Rated flow rate G30 (g/h)
73
131
284
Rated flow rate G31 (g/h)
71
129
279
Appliance set for:
G+ Groningen Group K gas
G25 (2L) - 25 mbar
G25.3 (2K) - 25 mbar
Содержание C7GMXNLK
Страница 44: ......