Instructions for the User
The display shows "- - - - " to indicate that there are no cooking
parameters present.
Press
START
or keep it pressed to increase the preheating temperature;
each time
START
is pressed the temperature increments by 5°C (from 30°
to 300°).
Press
STOP
to increase the number of minutes of cooking (N.B. if a
cooking time of 99 minutes is set, the cooking time will be infinite, meaning
that cooking can only be stopped in manual mode, by ending the program).
Release
STOP
and preheating will start automatically after 5 seconds.
N.B. – When the cooking process is over, to repeat the same program do
not turn the knob and press
START
again.
4.6
Editing a program
The programs the user is able to edit are from P6 to P8
A number of parameters can be edited for each program:
•
preheating temperature
[Uprh]
: User pre heating
•
cooking temperature
[U t°C]
User heating
•
cooking time
[U Ct]
: User cooking time
To edit a program by entering the parameters exactly as required, turn the
knob to one of the programs from P1 to P9.
The display shows the parameters contained in the selected program.
Hold down
STOP
for 2 seconds.
The display shows
U t°C
.
Press
START
to display the cooking temperature.
Press
START
or keep it pressed to increase the cooking temperature;
each time
START
is pressed the temperature increments by 1°C (from 50°
to 300°), or hold
START
down for increments of 5°C.
Press
STOP
to move on to displaying the next parameter.
The display shows
U Ct
.
Press
START
to display the cooking time.
Press
START
or keep it pressed to increase the cooking time (from 1 min.
to 99 min.).
Press
STOP
to complete the program editing procedure.
The display shows
UEnd
.
The parameters set are now saved in the chosen program.
Press
START
to display the parameters just set.
Press
START
again to run the program just edited.
4.7
Modifying a previously edited program
To modify one of the programs, turn the knob to one of the programs from
P1 to P9 edited previously.
The parameters saved earlier will appear on the display.
Hold down
STOP
for 2 seconds.
28