Smeg ALFA 200XE Скачать руководство пользователя страница 9

 

 

Instructions for the User

 

 

28

 

 

 

To edit a humidified fan-mode program by entering the parameters exactly 
as required, turn the knob to one of the programs from P1 to P14. 
The display shows the parameters contained in the selected program. 
Hold down STOP for 2 seconds. 
A beeper sounds to indicate that the editing mode has been accessed, 
and the message Ut°C appears on the display. 
Press START to display the cooking temperature. 
Press  START or keep it pressed to increase the cooking temperature; 
each time START is pressed the temperature increments by 1°C (from 50° 
to 300°), or hold START down for increments of 5°C.  (N.B. humidification 
cycles [U Ht] can only be edited if Ut°C  is set at a temperature above 
150°C). 
Press STOP to move on to displaying the next parameter 
The display shows U Ct
Press START to display the cooking time. 
Press START or keep it pressed to increase the cooking time (from 1 min. 
to 99 min.). 
Press STOP to move on to displaying the next parameter 
The display shows U Ht only if Ut°C is set > 150°C 
Press START to display the humidification cycles. 
Press START or keep it pressed to increase the number of humidification 
cycles (from 0 to 6 cycles where 0 means conventional fan-mode cooking 
without the aid of humidification). 
Press STOP to complete the program editing procedure. 

Содержание ALFA 200XE

Страница 1: ...___________ 26 5 CLEANING AND MAINTENANCE ___________________________ 33 6 EXTRAORDINARY MAINTENANCE _________________________ 36 INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified en...

Страница 2: ...OME SEPARATE THE VARIOUS WASTE PACKAGING MATERIALS BY TYPE AND CONSIGN THEM TO THE NEAREST SEPARATE DISPOSAL CENTRE THE APPLIANCE MUST BE CONNECTED TO EARTH IN COMPLIANCE WITH ELECTRICAL SYSTEM SAFETY...

Страница 3: ...ED WITH A PURIFIER SOFTENER SYSTEM ALFA 200XE THE OVEN S SIZE IS CALCULATED FOR A MAXIMUM LOAD OF 15 KG ALFA 135VE THE OVEN S SIZE IS CALCULATED FOR A MAXIMUM LOAD OF 7 KG BEFORE THE APPLIANCE IS PUT...

Страница 4: ...e cable of 5 x 1 5 mm2 In case of connection to the electrical mains by means of socket and pin the connection must be completed with a plug of suitable rating The power supply plug and wall socket mu...

Страница 5: ...m 2 4 Connection to the water supply Connect the water inlet connection on the rear to a water supply outlet having gas threaded connection taking care to screw tightly to the hose If the water supply...

Страница 6: ...lure scroll through preset programs and start cooking cycles DISPLAY Displays the current time the selected program the cooking parameters of the selected program and for 90 cm models only the operati...

Страница 7: ...inutes after the buzzer sounds or after the pilot light goes out before starting cooking processes 4 4 Setting the time At first use or after a power failure the time must be set The display will show...

Страница 8: ...for humidified fan mode cooking P1 to P14 1 manual editable program for fan mode cooking The following table shows the parameters for each program Uprh preheating temperature Ut C cooking temperature...

Страница 9: ...s by 1 C from 50 to 300 or hold START down for increments of 5 C N B humidification cycles U Ht can only be edited if Ut C is set at a temperature above 150 C Press STOP to move on to displaying the n...

Страница 10: ...splay shows the time left until the end of the cooking process the temperature set the number of humidification cycles set if any and the number of the program being used in alternation While cooking...

Страница 11: ...ing temperature each time START is pressed the temperature increments by 1 C from 50 to 300 or hold START down for increments of 5 C Press STOP to move on to displaying the next parameter The display...

Страница 12: ...e cooking time is required Release STOP and preheating will start automatically after 5 seconds the oven will preheat to the set cooking temperature N B When the cooking process is over to repeat the...

Страница 13: ...This message appears whenever the software detects that the sensor connector is not properly connected to the electronic circuit board or has short circuited This error resets automatically when the o...

Страница 14: ...fter allowing it to cool When cleaning and caring for stainless steel surfaces always use only specific products which do not contain abrasives or chlorine based acids Instructions for use pour the pr...

Страница 15: ...n it must be cleaned regularly at the end of each day after allowing it to cool Remove all removable parts Remove the side runners by lifting them and sliding them off the supporting pins as shown her...

Страница 16: ...ndow can be opened This means that each pane of glass can be cleaned on both the inside and the outside To open the inside pane simply gently pull out the two points shown in figure 1 After cleaning t...

Страница 17: ...uch as gaskets light bulbs etc The specific operations for each procedure of this kind are provided below Before carrying out any operation disconnect the oven from the electricity supply 6 1 Changing...

Отзывы: