Instructions for the installer
98
POSSIBLE
CONNECTION TYPES
CABLE TYPE
(if not present)
380
-
415 V
3N~
5-pole
5 x 1.5
mm²
H05V2V2-F
380
-
415 V
2N~
4-pole
4 x 1.5
mm²
H05V2V2-F
220
-
240 V
1N~
3-pole
3 x 2.5
mm²
H05V2V2-F
• Use H05V2V2-F cables withstanding temperatures of 90°C or higher.
• The values indicated above refer to the cross-section of the internal
conductor.
• The tightening torque of the screws of the terminal supply wires must be 1.5
- 2 Nm.
The aforementioned power cables are sized taking into account the coincidence
factor (in compliance with standard EN 60335-2-6).
11.5 Positioning the skirt
• Position the skirt above the top, taking
care to align holes
A
with holes
B
.
• Secure the skirt to the top by tightening
screws
C
.