background image

Compact Pressure Switch  

Series

 ZSE1/ISE1

ON

OFF

Caution

Calibration Procedure

SE1(L)-      -14/-15/-18/-19

I

Z

 

Set  the  ON-pressure  by  the  pressure  setting  trimmer.  Turning 

clockwise can set the high pressure/high vacuum pressure.

 

In the event of setting, use a flat head screwdriver suited for the 

groove of a trimmer, and rotate it lightly with a fingertip.

 

Switches with variable hysteresis can be adjusted by means of 

the  HYS  potentiometer  in  the  range  1  to  10%  of  the  setting 

pressure range.

 

Readjust  the  ON-pressure  setting  when  the  hysteresis  setting 

trimmer was changed after setting the ON pressure.

Hysteresis setting trimmer

Pressure setting trimmer

SET

HYS

Indicator light

SE1(L)-      16/-17

 

With  pressure  setting  trimmer  1  (SET  1),  OUT  1  (Black  lead 

wire, Red LED) can be set. 

 

With  pressure  setting  trimmer  2  (SET  2),  OUT  2  (White  lead 

wire, Green LED) can be set. 

I

Z

Pressure setting trimmer 2

Pressure setting trimmer 1

SET1

SET2

Indicator light

Set point

Supply pressure

Atmospheric 
pressure

0

Unsteady 
adsorption

Non adsorption

Steady adsorption

High v

acuum

 

Regarding the pressure setting

 

Set the possible min. pressure for adsorption confirmation. If 

setting the pressure lower than that, switch becomes ON in 

case that adsorption is not completely done. If setting the pres-

sure higher than that, switch does not become ON even though 

it may absorb workpieces.

Observe  the  following  precautions  for  setting  the  vacuum  pres-

sure:

Use your fingertips to gently turn the screwdriver.

Do not use a screwdriver with a large grip or with a tip that does 

not fit into the trimmer groove because this could strip the groove.

Hysteresis

Hysteresis  is  the  pressure  difference  between  the  ON  and    the 

OFF pressure of the output signal. The set pressure is the pres-

sure selected to switch from OFF to ON condition.

Set point

Atmospheric 

pressure 0

High v

accum

Hysteresis

High  pressure

How to Use Connector

1. Attaching and detaching connectors

 

When  assembling  the  connector  to  the  switch  housing,  push 

the connector straight onto the pins until the lever locks into the 

housing slot.

 

When  removing  the  connector  from  the  switch  housing,  push 

the lever down to unlock it from the slot and then withdraw the 

connector straight off of the pin.

Lead wire 0.2 to 0.33 mm

2

Max. coating O.D.
ø1.7 mm

0.2 to 0.33 mm

2

Max. coating O.D.
ø1.7 mm

Socket

Connector
DC polarity indicator

Lever

Hook

Hook

Lead wire

Socket

Connector
DC polarity indicator

Lever
Pin

Slot

Housing

Lead wire

Socket

Covering retainer

Core wire crimping area

Hook

Covering

Core wire

2. Crimping of lead wires and sockets

Strip 3.2 to 3.7 mm at the end of the lead wires, insert the ends 

of the core wires evenly into the sockets, and then crimp with a 

crimping tool. When this is done, take care that the coverings of 

the lead wires do not enter the core wire crimping area. 

(Crimping tool: model no. DXT170-75-1) 

Connector

Lead wire

Socket

Hook

3.Attaching and detaching lead wires with sockets

 

Attaching

Insert the sockets into the square holes of the connector (with 

+,  1,  2,  –  indication),  and  continue  to  push  the  sockets  all  the 

way in until they lock by hooking into the seats in the connector. 

(When they are pushed in their hooks open and they are locked 

automatically.)  Then  confirm  that  they  are  locked  by  pulling 

lightly on the lead wires.   

 

Detaching

To  detach  a  socket  from  a  connector,  pull  out  the  lead  wire 

while  pressing  the  socket’s  hook  with  a  stick  having  a  thin  tip 

(about 1 mm). If the socket will be used again, first spread the 

hook outward.  

849

ZSE30

ISE30
ZSE40

ISE40
ZSE10

ISE10

ISE70

ZSE80

ISE80
ZSE

ISE

ZSP

PS

ISA2

PSE

IS

ISG

ZSM1

ZSE

ISE

Содержание ZSE1 Series

Страница 1: ...with ZM ejector system Variable hysteresis 1 to 10 of set pressure Variable Easy and simple wiring Connector type Series ZSE1 For Vacuum ISE1 For Positive Pressure Compact Pressure Switch For General Pneumatics RoHS 846 ...

Страница 2: ...h Nil 30 50 0 6 m 3 m 5 m Note 1 M5 x 0 8 female threaded Note 2 Single mounting style M5 x 0 8 female threaded Positive pressure Vacuum NPN open collector 1 output w o analog output 3 turns adjustment NPN open collector 1 output w o analog output 200 degrees adjustment NPN open collector 2 output w o analog output 3 turns adjustment NPN open collector 2 output w o analog output 200 degrees adjust...

Страница 3: ...60 C With no condensation and no freezing Operating Stored 35 to 85 RH With no condensation 3 F S or less 1000 VAC for 1 min between terminals and housing 50 MΩ or more 500 VDC measured via megohmmeter between terminals and housing 01 R 8 M5 x 0 8 T1 NPTF 1 8 M5 x 0 8 00 ZM ejector mount type 40 g Including 0 6 m Long lead wire Heat resistant vinyl electric wire 4 wire Conductor area 0 3 mm2 Insul...

Страница 4: ... of the output signal The set pressure is the pres sure selected to switch from OFF to ON condition Set point Atmospheric pressure 0 High vaccum Hysteresis High pressure How to Use Connector 1 Attaching and detaching connectors When assembling the connector to the switch housing push the connector straight onto the pins until the lever locks into the housing slot When removing the connector from t...

Страница 5: ...rown DC Black OUT1 White OUT2 Blue DC Load Main circuit Main circuit Main circuit Main circuit Compact Pressure Switch Series ZSE1 ISE1 Internal Circuits and Wiring Examples 14 15 NPN 1 output 16 17 NPN 2 outputs 18 19 NPN 1 output Analog voltage output 55 PNP 1 output 849 1 ZSE30 ISE30 ZSE40 ISE40 ZSE10 ISE10 ISE70 ZSE80 ISE80 ZSE ISE ZSP PS ISA2 PSE IS ISG ZSM1 ZSE ISE A ...

Страница 6: ...setting trimmer Pressure setting trimmer 2 Pressure setting trimmer 1 Indicator light Red Green Pressure supply port ø2 O ring 2 x M2 5 x 24L Mounting threads Pressure supply port ø2 O ring 2 x M2 5 x 24L Mounting threads Connector type SE1 14C 15C 18C 19C I Z I Z Grommet type SE1 14 15 18 19 01 T1 01 T1 SE1 01 16C 17C SE1 01 16 17 I Z I Z Pressure setting trimmer Indicator light Red Hysteresis se...

Отзывы: