8
(8) Output terminal block (M3 terminal block)
Output terminal block for cascade trigger signal.
Electrical Standard: O/C DC5V 25mA or less
(9) Dip switch for setting cascade or temporary stop.
Operation is changed by the combination of the switches.
1
2
3
Operating conditions:
ON
ON
OFF Cascade base
ON
OFF
OFF Cascade remote
OFF
ON
OFF Temporary stop (external power)
OFF
ON
ON
Temporary stop (internal power)
OFF
OFF
OFF Single Operation
(10)DIP switch for setting
Set the number of energisations (1 or 2) for each output.ON side: twice, OFF side: once
(11)Set the rotary switch (Refer to 6-4).
Set the number of outputs.
(12) Digital switch for setting ON time
Set the output time for the valve.
Set for 6 or 10 points at once.
(13) Digital switch for setting OFF time
Set the pause time between outputs.
Set for 6 or 10 points at once.
(14) Status display LED
Lights up when cascading connection settings are enabled. (Display color: Green)
(15)Cascade input display LED
Lights up when cascade trigger signal is input. (Display color: Green)
Also lights up when a temporary stop signal is input.
(16) Cascade output display LED
Lights up when cascade trigger signal is output. (Display color: Green)
(17) Power fuse
〔
125V/1A
〕
If they become damaged, please replace them.