Applicable fluids

VX21/22/23, 2 Port solenoid valves

Standard

Water (standard, up to 60°C), air (standard, dry),
turbine oil, spindle oil, Kerosene, vacuum (up to 1 
torr), carbon dioxide (CO

2

), nitrogen gas (n

2

),

Freon 11, 113, 114

Fluid

Option symbol

Steam

(S,Q)

Vacuum (up to 10

-3

torr)

(V,M)

Option

Non-leak (10

-5

atm cc/sec or less)

(V,M)

High temperature water

(X,E,N,P)

High temperature oil

(D,N)

Others

VVX21/22/23 Manifold series

Generally, the recommended viscosity of fluid is 50 cSt max. Fluids
contaminated with foreign material can promote wear of the valve
seat and iron core. To prevent this, place a filter/strainer immediately
before the valve. A  mesh of 80-100 micron is recommended.
SMC valves are designed for use without lubricant. However, correctly
lubricated air will increase the life of the valve.

CAUTION

These valves are NOT EXPLOSION PROOF. When using inflammable oil
or gas, ensure that there is no leakage either inside or outside of the
valve.

Fluid temperature

Refer to the temperature range for each model. The temperature range
changes according to the sealing material, coil insulation, power 
supply, etc.

Ambient conditions

Freezing. When using water in cold environments anti-freeze precau-
tions should be taken. These include but are not limited to, draining of
pumps and valves. When using a heater, avoid applying it to the coil.
Freezing will result when the dew point of the medium is high and the
ambient  temperature is low or when a large volume of fluid flows
within the valve. In such cases install a dryer, keep the valve body
warm, or take other preventative measures.

Long period energisation or de-energisation

The valve energisation period depends on the type and viscosity of the
fluid. When pure water is the medium, then the valve should be
switched at least every 10 days. If the period is longer than 10 days, a
system check mechanism should be implemented.

CAUTION

These valves are not intended for use as emergency system valves.

Vibration

These valves should not be subjected to more than 3G and in the case
of non-leak type no more than 1G.

Fig 7

n-

1/

8

1/

4

(OUT Port)

H

(Pitch)

F

F

E

T

W

D

(44)

34.5

DIN connector

Terminal

Conduit

Grommet

Blanking plate

When you enquire about the product, please contact the following 

SMC Corporation

:

ENGLAND

Phone 01908-563888

TURKEY

Phone 212-2211512

ITALY

Phone 02-92711

GERMANY

Phone 6103-402-0

HOLLAND

Phone 020-5318888

FRANCE

Phone 01-64-76-10-00

SWITZERLAND

Phone 052-34-0022

SWEDEN

Phone 08-603 07 00

SPAIN

Phone 945-184100

AUSTRIA

Phone 02262-62-280

Phone 902-255255

IRELAND

Phone 01-4501822

GREECE

Phone 01-3426076

DENMARK

Phone 8738-0800

FINLAND

Phone 09-68 10 21

NORWAY

Phone 67-12 90 20

BELGIUM

Phone 03-3551464

POLAND

Phone 48-22-6131847

Отзывы: