SMC Networks VQC1000 Скачать руководство пользователя страница 13

 

- 12 -

 

No.VQC1000V-OMM0002-B 

 

 
 
 
 

1. These products are intended for use in general factory 

automation equipment. 

Avoid using these products in machinery/equipment which 
affects human safety, and in cases where malfunction or failure 
can result in extensive damage. 

2. Do not use in explosive environments, in the presence of 

inflammable gases, or in corrosive environments. This can 
cause injury or fire. 

3. Work such as transporting, installing, piping, wiring, 

operation, control and maintenance should be performed 
by knowledgeable and qualified personnel only. As 
handling involves the risk of a danger of electrocution, 
injury or fire. 

4. Install an external emergency stop circuit that can promptly 

stop operation and shut off the power supply. 

5. Do not modify these products. Modifications done to these 

products carry the risk of injury and damage.

 

 
 
 

1. Read the instruction manual carefully, strictly observe the 

precautions and operate within the range of the 
specifications. 

2. Do not drop these products or submit them to strong 

impacts. This can cause damage, failure or malfunction. 

3. In locations with poor electrical conditions, take steps to 

ensure a steady flow of the rated power supply. Use of a 
voltage outside of the specifications can cause malfunction, 
damage to the unit, electrocution or fire. 

4. Do not touch connector terminals or internal circuit 

elements when current is being supplied. There is a danger 
of malfunction, damage to the unit or electrocution if 
connector terminals or internal circuit elements are 
touched when current is being supplied. 

Be sure that the power supply is OFF when adding or removing 
manifold valves or input blocks or when connecting or 
disconnecting connectors. 

5. Operate at an ambient temperature that is within the 

specifications. Even when the ambient temperature range 
is within the specifications, do not use in locations where 
there are rapid temperature changes. 

6. Keep wire scraps and other extraneous materials from 

getting inside these products. This can cause fire, failure or 
malfunction. 

7. Give consideration to the operating environment 

depending on the type of enclosure being used. 

To achieve IP65 and IP67 protection class, provide appropriate 

wiring between all units using electrical wiring cables, 
communication connectors and cables with M12 connectors. 
Also, provide waterproof caps when there are unused ports, and 
perform proper mounting of input units, input blocks, SI units and 
manifold valves. Provide a cover or other protection for 
applications in which there is constant exposure to water. 

8. Use the proper tightening torques. 

There is a possibility of damaging threads if tightening exceeds 
the tightening torque range. 

9. Provide adequate protection when operating in locations 

such as follows: 

   

• Where noise is generated by static electricity 

   

• Where there is a strong electric field 

   

• Where there is a danger of exposure to radiation 
• When in close proximity to power supply lines 

10. When these products are installed in equipment, provide 

adequate protection against noise by using noise filters.

 

11. Since these products are components whose end usage 

is obtained after installation in other equipment, the 
customer should confirm conformity to EMC directives for 
the finished product. 

 
 
 
12. Do not remove the name plate. 
13. Perform periodic inspections and confirm normal 

operation, otherwise it may be impossible to guarantee 
safety due to unexpected malfunction or erroneous 
operation. 

14. Do not use in places where there are cyclic temperature 

changes. 

In case that the cyclic temperature is beyond normal 

temperature changes, the inside product is likely to be 
adversely effected. 

15. Do not use in direct sunlight. 

Do not use in direct sunlight. It may cause malfunction or 

damage. 

16. Do not use in places where there is radiated heat around 

it. 

Such a place is likely to cause malfunction. 

 

Safety Instructions on Power Supply 

 
 

1. Operation is possible with a single power supply or a 

separate power supply. However, be sure to provide two 
wiring systems (one for solenoid valves, and one for input 
and control units). 

2. When it is UL compliant, use a class 2 power supply unit in 

accordance with UL1310 for a combined direct current 
power supply.   

 

Safety Instructions on Cable 

 
 

1. Avoid miswiring, as this can cause malfunction, damage 

and fire in the unit. 

2. To prevent noise and surge in signal lines, keep all wiring 

separate from power lines and high-voltage lines. 
Otherwise, this can cause malfunction.   

3. Check wiring insulation, as defective insulation can cause 

damage to the unit when excessive voltage or current is 
applied. 

4. Do not bend or pull cables repeatedly, and do not place 

heavy objects on them or allow them to be pinched. This 
can cause broken lines.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

EX500/EX250/EX126 Precautions

 

 

 

 

 

 

VQC1000/2000 series 

Specific Product Precautions 4 

  Be sure to read this before handling 

Содержание VQC1000

Страница 1: ...Doc No VQC1000V OMM0002 B PRODUCT NAME Solenoid Valve MODEL Series VQC1000 2000 Series Pilot Valve V100...

Страница 2: ...2 3 Precautions on Design 4 5 Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 7 Air Supply 7 Operating Environment 7 Maintenance 7 8 Specific Product Precautions 9 15 Valve construction 16...

Страница 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Страница 4: ...re of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from...

Страница 5: ...sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Regarding vacuum switch valves and vacuum release valves If a non vacuum valve is installed in the middle of a piping sys...

Страница 6: ...n internal pilot type valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to th...

Страница 7: ...reference value for the tightening torque refer to the table below 2 The gasket can be reused up to 6 to 10 times It can be replaced easily when it has sustained damage A broken gasket can be removed...

Страница 8: ...alve and cause it to malfunction For compressed air quality refer to the SMC Best Pneumatics No 6 catalog Operating Environment 1 Do not use in an atmosphere containing corrosive gases chemicals sea w...

Страница 9: ...n the valve to confirm the operating condition and check for any air leakage 1 Drain flushing Remove drainage from the air filters regularly 2 Lubrication In the case of rubber seals once lubrication...

Страница 10: ...ON side with a small flat head screwdriver or with your fingers Slide it to the fitting side OFF side to release it In addition it can also be used as a push type by using a screwdriver etc of 1 7 or...

Страница 11: ...rings must be free from scratches and dust Otherwise air leakage may result 2 After screwing in the fittings mount the M5 fitting assembly on the manifold base Tightening torque 0 8 to 1 2 N m 3 Purc...

Страница 12: ...ated in the end plate on both sides of the manifold base A dirty and choked element may reduce cylinder speed or cause malfunction Clean or replace the dirty element How to Calculate Flow Rate Convers...

Страница 13: ...ide waterproof caps when there are unused ports and perform proper mounting of input units input blocks SI units and manifold valves Provide a cover or other protection for applications in which there...

Страница 14: ...kely damage the product IP67 protection class cannot be guaranteed if the screws are not tightened to the specified torque 4 When lifting a large size manifold solenoid valve unit take care to avoid c...

Страница 15: ...a surge generating load is directly driven the unit may be damaged 7 The product is CE marked but not immune to lightning strikes Take measures against lightning strikes in your system 8 Keep dust wir...

Страница 16: ...units take care not to get fingers caught between units Injury can result 2 Perform periodic inspection Unexpected malfunction in the system composition devices is likely to occur due to malfunction o...

Страница 17: ...16 No VQC1000V OMM0001 B...

Страница 18: ...17 No VQC1000V OMM0001 B...

Страница 19: ...18 No VQC1000V OMM0001 B...

Страница 20: ...19 No VQC1000V OMM0001 B...

Страница 21: ...20 No VQC1000V OMM0001 B...

Страница 22: ...21 No VQC1000V OMM0001 B...

Страница 23: ...22 No VQC1000V OMM0001 B...

Страница 24: ...23 No VQC1000V OMM0001 B...

Страница 25: ...24 No VQC1000V OMM0001 B...

Страница 26: ...25 No VQC1000V OMM0001 B...

Страница 27: ...26 No VQC1000V OMM0001 B...

Страница 28: ...27 No VQC1000V OMM0001 B...

Страница 29: ...28 No VQC1000V OMM0001 B...

Страница 30: ...29 No VQC1000V OMM0001 B...