SMC Networks TRTU Series Скачать руководство пользователя страница 2

2R

Middle layer

Aluminum laminated film

Outer layer

Flame resistant polyolefin
(Equivalent to UL-94 standard V-0)

Inner tube

Polyurethane

For general pneumatic and water
piping in environments exposed
to sparks from arc welding, etc.

Fix

ed end

Note 1) Applicable for general industrial water. Please consult with SMC if using for the other kind 

of fluid. Also, the surge pressure must be under the maximum operating pressure.
If the surge pressure exceeds the maximum operating pressure, it will result in damage to 
fittings and tubes.

Note 2) The minimum bending radius is the representative value measured as shown in the left 

figure. Allow extra length when piping since the tube may be bent if used under the 
minimum bending radius. 

Note 3) The color of all inner tubes is black.

Model

Specifications

 — 20 m roll  

 — 100 m reel

Model

TRTU1208

12

8

1

TRTU1065

10

6.5

1

TRTU0805

8

5

1

TRTU0604

6

4

1

Inner tube O.D. (mm)

Inner tube I.D. (mm)

Outer layer thickness (mm)

Black (B) 

White (W) 

Red (R) 

Blue (BU) 

Yellow (Y) 

Green (G) 

Outer
layer
color

Fluid 

Note 1)

Burst pressure

Min. bending radius (mm) 

Note 2)

Ambient and fluid temperature

Material

Applicable fittings

Max. operating 
pressure

At 20

°

C

At 40

°

C

At 60

°

C

Inner tube

Middle layer

Outer layer

Air, Water

0.8 MPa

0.65 MPa

0.5 MPa

Refer to the burst pressure characteristics curve.

−20 to +60°C   Water: 0 to 40°C (No freezing) 

Polyurethane

Aluminum laminated film

Polyolefin (Equivalent to UL-94 standard V-0)

50

60

70

80

FR one-touch fittings: Series KR-W2

Metal one-touch fittings: Series KQB2

How to Order

TRTU1065 B

20

Tubing model

TRTU0604
TRTU0805
TRTU1065
TRTU1208

Color

Symbol

B

W

R

BU

Y

G

Color

Black 

White

Red

Blue

Yellow
Green

Length per roll

Symbol

20

100

Length

20 m roll

100 m reel

Bend the tube into the U-form at a 
temperature of 20°C. Fix one end and 
close loop gradually. Measure 2R when 
the deformed ratio of the tube diameter at 
bending reaches 5%.

How to measure the

minimum bending radius

Burst Pressure Characteristics
Curve and Operating Pressure

Note 3)

0.0

1.0

2.0

3.0

4.0

−20

0

20

40

60

Operating temperature (

°

C)

Pressure (MP

a)

Max. operating pressure

Burst pressure

RoHS

Model

Inner tube O.D. x I.D. (mm)

6 x 4
8 x 5

10 x 6.5

12 x 8

1

Series

TRTU

Flame Resistant (Equivalent to UL-94 Standard V-0)
FR Three-layer  Polyurethane Tubing

TRTU-A.qxd  10.7.22 5:21 PM  Page 2

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com