3-1
C
HAPTER
3
I
NSTALLING
THE
S
WITCH
Selecting a Site
Switch units can be mounted in a standard 19-inch equipment rack or on a
flat surface. Be sure to follow the guidelines below when choosing a
location.
•
The site should:
-
be at the center of all the devices you want to link and near a
power outlet.
-
be able to maintain its temperature within 0 to 50 °C (32 to
122 °F) and its humidity within 10% to 90%, non-condensing
-
provide adequate space (approximately two inches) on all sides for
proper air flow
-
be accessible for installing, cabling and maintaining the devices
-
allow the status LEDs to be clearly visible
•
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios and transmitters.
•
Make sure that the unit is connected to a separate grounded power
outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m
(6.6 feet) of each device and is powered from an independent circuit
breaker. As with any equipment, using a filter or surge suppressor is
recommended.
Содержание TigerSwitch SMC6726AL2
Страница 2: ......
Страница 14: ...COMPLIANCES x ...
Страница 20: ...FIGURES xvi ...
Страница 28: ...ABOUT THE TIGERSWITCH 10 100 1 8 ...
Страница 64: ...SPECIFICATIONS C 4 ...
Страница 66: ...ORDERING INFORMATION D 2 ...
Страница 72: ...GLOSSARY Glossary 6 ...
Страница 76: ...INDEX Index 4 ...
Страница 77: ......