38 Tesla

Irvine, CA 92618

All rights reserved. Printed in Taiwan

Trademarks:

SMC is a registered trademark; TigerSwitch isa a trademarks of SMC Networks, Inc. Other product and 
company names are trademarks or registered trademarks of their respective holders.

Содержание TigerSwitch 10 SMC6724L3

Страница 1: ...gregate bandwidth Non blocking switching architecture Spanning Tree Protocol Up to six LACP or static 4 port trunks Port mirroring for non intrusive analysis Layer 2 3 4 CoS support through four prior...

Страница 2: ......

Страница 3: ...38 Tesla Irvine CA 92618 Phone 949 679 8000 TigerSwitch 10 100 Installation Guide From SMC s Tiger line of feature rich workgroup LAN solutions May 2003 Pub 150200033800A...

Страница 4: ...ense is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2003 by SMC Networks Inc 38 Te...

Страница 5: ...corporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of discontinua...

Страница 6: ...RE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DA...

Страница 7: ...e for RJ 45 connections Category 3 or greater for 10 Mbps connections Category 5 for 100 Mbps connections and Category 5 5e or 6 for 1000 Mbps Use 50 125 or 62 5 125 micron multimode fiber optic cable...

Страница 8: ...ording to EN 61000 3 2 1995 Limitation of voltage fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electr...

Страница 9: ...an VCCI Class A Taiwan BSMI Class A Australia AS NZS 3548 1995 Class A SMC contact for products in Australia is SMC Communications Pty Ltd Suite 18 12 Tryon Road Lindfield NSW2070 Phone 61 2 94160437...

Страница 10: ...port and fiber cable ends when they are powered on Ne regardez jamais le laser tant qu il est sous tension Ne regardez jamais directement le port TX Transmission fibres optiques et les embouts de c b...

Страница 11: ...raum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung vermieden 12 Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeiten i...

Страница 12: ...COMPLIANCES viii...

Страница 13: ...MSC 1 8 Optional 1000BASE X GBIC Module SMC6824GB 1 8 Optional Redundant Power Unit 1 9 Power Supply Receptacle 1 9 Features and Benefits 1 10 Connectivity 1 10 Expandability 1 10 Performance 1 11 Man...

Страница 14: ...ounting 3 3 Desktop or Shelf Mounting 3 5 Installing an Optional Module into the Switch 3 6 Installing a GBIC Transceiver 3 7 Connecting to a Power Source 3 8 4 Making Network Connections 4 1 Connecti...

Страница 15: ...ASE T Cable Requirements B 6 Cable Testing for Existing Category 5 Cable B 6 Adjusting Existing Category 5 Cabling B 6 Console Port Pin Assignments B 7 DB 9 Port Pin Assignments B 7 Console Port to 9...

Страница 16: ...TABLE OF CONTENTS x Glossary Index...

Страница 17: ...with full support for Spanning Tree Protocol Multicast Switching Virtual LANs and IP routing It brings order to poorly performing networks by segregating them into separate broadcast domains with IEEE...

Страница 18: ...th of each connection Auto negotiation is used to select the optimal transmission speed and communication mode for each connection With store and forward switching and flow control maximum data integr...

Страница 19: ...ork connection in band using Telnet the on board Web agent or Windows based network management software The management agent provides a wide range of advanced performance enhancing features Port based...

Страница 20: ...hubs See 10BASE T 100BASE TX Pin Assignments on page B 2 Each of these ports support IEEE 802 3x auto negotiation so the optimum transmission mode half or full duplex and data rate 10 or 100 Mbps can...

Страница 21: ...Mbps network connection Flashing Green Port has established a valid 10 Mbps network connection Activity Flashing Yellow Traffic is passing through the port Module Ports Link On Yellow Port has establi...

Страница 22: ...Off Power off or failure RPU On The redundant power supply is operating normally On Amber The redundant power supply has failed Off No redundant power supply is connected Diag On Green The system dia...

Страница 23: ...s it supports auto negotiation of speed duplex mode i e half or full duplex and flow control Note that you should first test the cable installation for IEEE 802 3ab compliance See 1000BASE T Cable Req...

Страница 24: ...091 Optional 1000BASE X GBIC Module SMC6824GB Figure 1 7 Single Port 1000BASE X GBIC Module This module supports 5 V 1000BASE SX and 1000BASE LX GBIC transceivers 1000BASE SX GBIC transceivers provid...

Страница 25: ...1 miles away with single mode fiber cable Caution Install only 5 V GBIC transceivers into the module slots Optional Redundant Power Unit An optional Redundant Power Unit RPU is available that can sup...

Страница 26: ...802 3 Ethernet 802 3u Fast Ethernet 802 3z and 802 3ab Gigabit Ethernet compliance ensures compatibility with standards based hubs network cards and switches from any vendor Expandability Optional si...

Страница 27: ...gotiation for flow control Performance Transparent bridging Aggregate bandwidth of up to 8 8 Gbps Switching table with a total of 8K MAC address entries and 2K IP address entries Provides store and fo...

Страница 28: ...ic VLAN learning and private VLANs IP based Layer 3 routing OSPFv2 and DVMRP Quality of Service QoS supports two levels of priority and Weighted Round Robin queueing Layer 3 4 traffic prioritization w...

Страница 29: ...can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize throughput When networks are based on repeater hub technolog...

Страница 30: ...ly build on this basic configuration adding direct full duplex connections to workstations or servers When the time comes for further expansion just cascade the switch to an Ethernet or Fast Ethernet...

Страница 31: ...x network down into a single efficient bridged node increasing overall bandwidth and throughput In the figure below the 10BASE T 100BASE TX ports on the switch are providing 100 Mbps connectivity for...

Страница 32: ...or 1000BASE LH GBIC module can be used to interconnect remote network segments While a 1000BASE SX module can be used for a high speed connection between floors in the same building and a 1000BASE LX...

Страница 33: ...itches you need to make a separate connection for each VLAN group This approach is however inconsistent with the Spanning Tree Protocol which can easily segregate ports that belong to the same VLAN Wh...

Страница 34: ...otocols and a gateway router linked to the WAN Just assign an IP address to any VLANs that need to communicate The switch will continue to segregate Layer 2 traffic based on VLANs but will now provide...

Страница 35: ...idth Maximum Cable Length 62 5 125 micron 160 MHz km 2 220 m 7 722 ft 200 MHz km 2 275 m 7 902 ft 50 125 micron 400 MHz km 2 500 m 7 1641 ft 500 MHz km 2 550 m 7 1805 ft Maximum Fiber Optic Cable Dist...

Страница 36: ...e Type Max Cable Length 10BASE T Twisted Pair Category 3 or better 100 m 328 ft 100BASE TX Category 5 or better 100 ohm UTP or STP 100 m 328 ft 100BASE FX Multimode 50 125 or 62 5 125 micron core mult...

Страница 37: ...IP subnets you can take advantage of the wire speed Layer 3 routing provided by this switch 4 The multimode fiber modules are fitted with SC connectors but you can attach an ST plug to the switch usin...

Страница 38: ...NETWORK PLANNING 2 10...

Страница 39: ...ng provide adequate space approximately two inches on all sides for proper air flow be accessible for installing cabling and maintaining the devices allow the status LEDs to be clearly visible Make su...

Страница 40: ...Kit containing two brackets and four screws for attaching the brackets to the switch Power Cord either US Continental Europe or UK RS 232 console cable This Installation Guide Management Guide SMC War...

Страница 41: ...the Switch on page 3 4 Rack Mounting Before rack mounting the switch pay particular attention to the following factors Temperature Since the temperature within a rack assembly may be higher than the...

Страница 42: ...ure 3 1 Attaching the Brackets 2 Mount the device in the rack using four rack mounting screws not provided Figure 3 2 Installing the Switch in a Rack 3 If installing a single switch only turn to Conne...

Страница 43: ...on a flat surface near an AC power source making sure there are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Connecting to a Power Source at...

Страница 44: ...a previously installed module from the appropriate slot by removing the two screws with a flat head screwdriver 3 Before opening the package that contains the module touch the bag to the switch casing...

Страница 45: ...at the transceiver is keyed so that it can only be installed in one orientation 2 Press in on the transceiver s side tabs and gently slide it into the GBIC interface slot until it clicks into place Ca...

Страница 46: ...socket Note For International use you may need to change the AC line cord You must use a line cord set that has been approved for the receptacle type in your country 3 Check the front panel LEDs as t...

Страница 47: ...equired for 10BASE T Category 3 or better cable can be used Cabling Guidelines A twisted pair connection between two ports must have a crossover of the transmit and receive wires to be able to functio...

Страница 48: ...se standard straight through twisted pair cables to connect to any other network device PCs servers switches hubs or routers However note that auto negotiation must be enabled on these ports for autom...

Страница 49: ...e next page Otherwise attach the other end to an available port on the switch 3 Make sure each twisted pair cable does not exceed 100 meters 328 ft in length Note When connected to a shared collision...

Страница 50: ...quipment follows 1 Attach one end of a patch cable to an available port on the switch and the other end to the patch panel 2 If not already in place attach one end of a cable segment to the back of th...

Страница 51: ...5 micron single mode fiber optic cable with an SC connector at both ends Warning This switch uses lasers to transmit signals over fiber optic cable The lasers are compliant with the requirements of a...

Страница 52: ...cable can be attached in only one orientation Figure 4 3 Making SC Port Connections 4 As a connection is made check the Activity LED on the switch s front panel for the corresponding module to be sure...

Страница 53: ...Contact SMC Technical Support Link LED is Off Verify that the switch and attached device are powered on Be sure the cable is plugged into both the switch and corresponding device If the switch is inst...

Страница 54: ...you are sure that all the other components are functioning properly In Band Access You can access the management agent in the switch from anywhere within the attached network using Telnet a Web browse...

Страница 55: ...n core single mode fiber SMF 20 km 12 43 miles SC 1000BASE SX 50 125 or 62 5 125 micron core MMF See the following table SC or ST 1000BASE LX 9 125 micron SMF 10 km 6 2 miles SC 1000BASE ZX 9 125 micr...

Страница 56: ...wire pair is identified by two different colors For example one wire might be red and the other red with white stripes Also an RJ 45 connector must be attached to both ends of the cable Caution Each...

Страница 57: ...s to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable Whe...

Страница 58: ...type Crossover Wiring If the twisted pair cable is to join two ports and either both ports are labeled with an X MDI X or neither port is labeled with an X MDI a crossover must be implemented in the...

Страница 59: ...smit and receive Use 100 ohm Category 5 or 5e unshielded twisted pair UTP or shielded twisted pair STP cable for 1000BASE T connections Also be sure that the length of any twisted pair connection does...

Страница 60: ...ts for Attenuation Near End Crosstalk NEXT and Far End Crosstalk FEXT This cable testing information is specified in the ANSI TIA EIA TSB 67 standard Additionally cables must also pass test parameters...

Страница 61: ...signments used to connect to the serial port are provided in the following tables Figure B 2 DB 9 Console Port Pin Numbers DB 9 Port Pin Assignments Console Port to 9 Pin DTE Port on PC EIA Circuit CC...

Страница 62: ...CABLES B 8 Console Port to 25 Pin DTE Port on PC Switch s 9 Pin Serial Port Null Modem PC s 25 Pin DTE Port 2 RXD TXD 2 TXD 3 TXD RXD 3 RXD 5 SGND SGND 7 SGND No other pins are used...

Страница 63: ...0BASE X GBIC Network Interface 10BASE T RJ 45 100 ohm UTP cable Categories 3 4 5 100BASE TX RJ 45 100 ohm UTP cable Category 5 Ports 1 24 RJ 45 connectors auto MDI MDI X Communication Speed 10 and 100...

Страница 64: ...50 C 32 to 122 F Storage 40 to 70 C 40 to 158 F Humidity Operating 5 to 95 Power Supply Internal auto ranging transformer 100 to 240 VAC 47 to 63 Hz Power Consumption 70 Watts maximum Maximum Current...

Страница 65: ...Supports four levels of priority and Weighted Round Robin Queueing which can be configured by VLAN tag or port Layer 3 4 priority mapping IP Precedence IP DSCP Management Features In Band Management...

Страница 66: ...3x full duplex flow control ISO IEC 8802 3 SNMP RFC 1157 ARP RFC 826 MIB II RFC 1213 Bridge MIB RFC 1493 Compliances CE Mark Emissions FCC Class A Industry Canada Class A EN55022 CISPR 22 Class A EN...

Страница 67: ...cation Mode Full duplex Network Interface SMC6824FSSC 9 125 micron single mode fiber cable SMC6824FMSC 50 125 or 62 5 125 micron multimode fiber cable Standards IEEE 802 3u Fast Ethernet ISO IEC 8802...

Страница 68: ...TP cable Category 5 5e or 6 Standards IEEE 802 3ab Gigabit Ethernet IEEE 802 3u Fast Ethernet IEEE 802 3 Ethernet 1000BASE X GBIC Module Model SMC6824GB Ports 1 slot for GBIC transceivers Communicatio...

Страница 69: ...e with one 100BASE FX single mode fiber port SC type connector SMC6824FMSC Extender module with one 100BASE FX multimode fiber port SC type connector SMC6824GB Gigabit module with one slot for GBIC tr...

Страница 70: ...ORDERING INFORMATION D 2...

Страница 71: ...trands of 50 125 or 62 5 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 125 micron core fiber cable 1000BASE LX IEEE 802 3z s...

Страница 72: ...Their interference makes both signals unintelligible Collision Domain Single CSMA CD LAN segment CSMA CD Carrier Sense Multiple Access Collision Detect is the communication method employed by Ethernet...

Страница 73: ...Negotiation to each port LAN segment Full Duplex Transmission method that allows switch and network card to transmit and receive concurrently effectively doubling the bandwidth of that link Gigabit Et...

Страница 74: ...Defines CSMA CD access method and physical layer specifications for 1000BASE Gigabit Ethernet LAN Segment Separate LAN or collision domain LED Light emitting diode used for monitoring a device or net...

Страница 75: ...nector A connector for twisted pair wiring Straight through Port An RJ 45 port which does not cross the receive and transmit signals internally so it can be connected with straight through twisted pai...

Страница 76: ...Glossary 6...

Страница 77: ...ing D 1 address table size C 1 adhesive feet attaching 3 5 air flow requirements 3 1 application examples 2 2 applications 2 2 collapsed backbone 2 2 remote connections with fiber 2 4 VLAN connections...

Страница 78: ...3 1 wiring closet connections 4 4 L laser safety 4 5 LED indicators Diag 1 6 problems A 1 PWR 1 6 RPU 1 6 limited warranty C 4 location requirements 3 1 M management agent 1 3 features 1 11 C 3 out o...

Страница 79: ...rack mounting 3 2 SC ST Converter 4 5 4 6 D 1 site selelction 3 1 SNMP agent 1 3 Spanning Tree Protocol 2 5 specifications 1000BASE X GBIC module C 6 compliances C 4 environmental C 2 physical C 1 po...

Страница 80: ...INDEX Index 4...

Страница 81: ......

Страница 82: ...38 32 32 Fax 33 0 41 38 01 58 Italy 39 0 335 5708602 Fax 39 02 739 14 17 Benelux 31 33 455 72 88 Fax 31 33 455 73 30 Central Europe 49 0 89 92861 0 Fax 49 0 89 92861 230 Nordic 46 0 868 70700 Fax 46 0...