Safety Instructions

These safety instructions are intended to prevent hazardous situations and/or equipment damage.
These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

 , and other safety regulations.

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

ISO 4413: Hydraulic fluid power -- General rules relating to systems.
IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)
ISO 10218: Manipulating industrial robots -Safety.

  etc.

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result

in minor or moderate injury.

 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could

result in death or serious injury.

 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result

in death or serious injury.

 

Warning

1. The compatibility of the product is the responsibility of the person who designs the equipment or

decides its specifications.

Since the product specified here is used under various operating conditions, its compatibility with specific
equipment must be decided by the person who designs the equipment or decides its specifications based on
necessary analysis and test results.
The expected performance and safety assurance of the equipment will be the responsibility of the person who
has determined its compatibility with the product.
This person should also continuously review all specifications of the product referring to its latest catalog
information, with a view to giving due consideration to any possibility of equipment failure when configuring the
equipment.

2. Only personnel with appropriate training should operate machinery and equipment.

The product specified here may become unsafe if handled incorrectly.
The assembly, operation and maintenance of machines or equipment including our products must be
performed by an operator who is appropriately trained and experienced.

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

1.The inspection and maintenance of machinery/equipment should only be performed after measures to

prevent falling or runaway of the driven objects have been confirmed.

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 

and the power from any appropriate source is cut, and read and understand the specific product precautions 
of all relevant products carefully.

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to

be used in any of the following conditions.

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to

direct sunlight.

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping,

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or
other applications unsuitable for the standard specifications described in the product catalog.

3. An application which could have negative effects on people, property, or animals requiring special safety

analysis.

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

-2- 

Содержание SX090 Series

Страница 1: ...Doc no SX90 OMY0004 PRODUCT NAME Low Profile 2 3 Port Solenoid Valve MODEL Series Product Number SX90 090 Series...

Страница 2: ...Instrucrions P4 Selection P4 Mounting P5 Piping P5 Wrining P6 Air Supply P6 Operating Enviroment P6 P7 Maintenance P7 How to order P8 Specifications P8 Dimensions P9 Specific Product Precautions P9 T...

Страница 3: ...failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembl...

Страница 4: ...the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this...

Страница 5: ...hing operation with the PWM control circuit inside the valve after the rated power has been applied for several tens of ms to reduce the power consump tion The problems shown below may occur in this t...

Страница 6: ...Mounting orientation The mounting orientation is universal 7 Initial lubrication of main valve The main valve is already applied initial lubricant Grease Caution 5 Warning 1 Operation manual Install...

Страница 7: ...4 Use clean ai Do not use compressed air that contains chemicals synthetic oils that include organic solvents salt corrosive gases etc as it can cause damage or malfunction Air Supply Caution 1 When e...

Страница 8: ...and electric power and exhaust all air pressure from the system using the residual pressure release function For the 3 position closed center or double check valve types exhaust the residual pressure...

Страница 9: ...VDC Rated 35 0 8 W Allowable voltage fluctuation 5 10 of rated voltage 0 to 10 Type of coil insulation Class B w e r SX9 1 5 G SX090 5 G q 2 port valve 3 port valve 1 For use with fluids other than ai...

Страница 10: ...duration Do not touch the valve by hand directly When there is such a dangerous case to be touched by hands directly install a protective cover 3 When using the solenoid valves on a manifold note tha...

Страница 11: ...oltage Incorrect selection of voltage Directly exposed to water Damage or deformation of external force Foreign matter got stuck in the valve valve becomes sticky Damage or deformation of external for...

Страница 12: ...ve 8 Replace the valve Protect the valve to prevent it from being exposed to water 9 Replace the valve Please do not apply force to the coil and frame when installing the piping and valves 10 Replace...

Страница 13: ...u Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacture...

Отзывы: