- 4 -
*1. Specifications
1-1. Cylinder specifications
Action
Double acting, double acting with spring, and single
acting (spring extended).
Fluid
Air
Proof pressure
1.5MPa
Max. Operating pressure
1.0Mpa
Ambient and operating fluid
temperature
Without auto switch
: -10
o
C to 70
o
with auto switch: -10
C/
o
C to 60
o
C
Lubrication
Not required (non-lube)
Cushion
Rubber bumper
Stroke length tolerance
+1.4
0
Mounting bracket
Through hole or both ends tapped style
Auto switch
Mountable
1-2. Single acting (Spring extended) spring force (N)
Bore size
Extended
Compressed
12
3.9
9.6
16
4.9
14.9
20
3.4
14.9
32
8.8
18.6
40.50
13.7
27.5
※
Applicable when the rod end configuration is round
bar type, chamfered type , roller type ,round bar type with
female thread or chamfered type with female thread.
2.Internal diameter and standard stroke (mm)
Bore
size
The rod end configuration
Round bar type
Chamfered type
Round bar type with female thread
Chamfered type with female thread
Roller type
Lever type with shock absorber
12
10
10
―
16
10.15
10.15
―
20
10,15,20
10,15,20
―
32
10,15,20
40
20,25,30
20,25,30
20,25,30
50
3. Operating air
The air supplied to the cylinder should be filtered by SMC AF series air filter and regulated to the
specified set pressure by SMC AR series regulator.
4. Speed adjustment
①
When the piston speed has to be adjusted, install an SMC AS series speed controller near the air
inlet port and adjust it to obtain the specified speed.
②
There are two ways to adjust the speed by using speed controller. One is by restricting the air
supplied
to the cylinder. The other is by restricting the air exhausted from the cylinder.
Supply air is restricted for single acting cylinder, and exhaust air is restricted for double acting cylinder.
5. Directional control
To switch the operating direction of the cylinder, mount an applicable solenoid valve selected from
SMC's range of solenoid valves. Generally, double acting cylinder is switched by 4 way solenoid valve.
Single acting type is switched by 3 way solenoid valve.