Installation
The RPU may be placed on a desktop or mounted in a rack.
Caution:
DO NOT place the RPU on the floor as the case is not
waterproof. It is recommended that this RPU be installed in
a network equipment rack.
Selecting a Site
RPU units can be mounted in a standard 19-inch equipment rack or on a
flat surface. Be sure to follow the guidelines below when choosing a
location.
•
The site should:
-
be at the center of all the devices you want to link and near a
power outlet.
-
be able to maintain its temperature within 0 to 45 °C (32 to
113 °F) and its humidity within 5% to 95%, non-condensing
-
provide adequate space (approximately two inches) on all sides for
proper air flow
-
be accessible for installing, cabling and maintaining the devices