background image

Sub 

screen

 

Selection of display on sub screen

The display on the sub screen in measuring mode can be set.

Set value display

Accumulated value display

Peak value display

Displays the set value. (The set 

value  of  OUT2  cannot  be  dis-

played.) 

Displays the accumulated val-

ue. (The accumulated value of 

OUT2 cannot be displayed.)

Displays the peak value.

Bottom value display

Line name display

OFF

Displays the bottom value.

Displays the line name. (Up to 
6 alphanumeric characters can 
be input.)

Displays nothing.

PFMC 

Series

Function Details

 

Output operation

The output operation can be selected from the following:
Output (hysteresis mode and window comparator mode) corresponding 
to  instantaneous  flow,  or  output  (accumulated  output  and  pulse 
output) corresponding to accumulated flow.

Note) At the time of shipment from the factory, it is set to hysteresis mode and normal output.

Green for ON, Red for OFF
Red for ON, Green for OFF

Red all the time

Green all the time

 

Display color

The  display  color  can  be  selected  for 
each  output  condition.  The  selection  of 
the  display  color  provides  visual  iden- 
tification  of  abnormal  values.  (The 
display color depends on OUT1 setting.)

 

External input function

This  function  can  be  used  only  when  the  optional  external  input  is 

present. The accumulated flow, peak value and bottom value can be 

reset remotely.

Accumulated  flow  external  reset: A  function  to  reset  the  accumulated  flow  value 

when an external input signal is applied.

In accumulated increment mode, the accumulated 

value will reset to, and increase from zero.

In accumulated decrement mode, the accumulated 

value will reset to, and decrease from the set value.

 When  the  accumulated  value  is  memorized,  every  time  the  accumulated 

flow  external  reset  is  activated,  the  memory  device  (EEPROM)  will  be 

accessed.  Take  into  consideration  the  maximum  number  of  times  the 

memory device can be accessed, 1 million times. The total of external input 

times and accumulated value memorizing time interval should not exceed 1 

million times.

Peak/Bottom reset: Peak and bottom value are reset.

 Forced output function

The output is turned on/off in a fixed state when starting the system 

or  during  maintenance.  This  enables  confirmation  of  the  wiring  and 

prevents system errors due to unexpected output.

For the analog output type, when ON the output will be 5 V or 20 mA, 

and when OFF, it will be 1 V or 4 mA.

 Also,  the  increase  or  decrease  of  the  flow  and  temperature  will  not 

change the on/off status of the output while the forced output function is 

activated.

 

Accumulated value hold

Accumulated  value  is  not  cleared  even  when  the  power  supply  is 
turned off.
The  accumulated  value  is  memorized  every  2  or  5  minutes  during 
measurement,  and  continues  from  the  last  memorized  value  when 
the power supply is turned on again.
The life time of the memory element is 1 million access cycles. Take 
this into consideration before using this function.

 

Display OFF mode

This function will turn the display OFF. In this mode, decimal points 
flash on the main screen. If any button is pressed during this mode, 
the display reverts to normal for 30 seconds to allow checking of the 
flow etc.

 

Setting of security code

The  user  can  select  whether  a  security  code  must  be  entered  to 
release  key  lock.  At  the  time  of  shipment  from  the  factory,  it  is  set 
such that the security code is not required.

 

Peak/Bottom value display

The  maximum  (minimum)  flow  rate  is  detected  and  updated  from 
when the power supply is turned on. In peak (bottom) value display 
mode, this maximum (minimum) flow rate is displayed.

 

Keylock function

Prevents operation errors such as accidentally changing setting values.

Standard condition: Flow rate converted to a volume at 20

°

C and 1 atm (atmosphere)

Normal condition: Flow rate converted to a volume at 0

°

C and 1 atm (atmosphere)

 

Reference condition

The  display  unit  can  be  selected  from  standard  condition  or  normal 
condition.

 

Display mode

The display mode can be selected from 
instantaneous flow or accumulated flow.

Instantaneous flow display

Accumulated flow display

 

Response time

The response time can be selected to suit the application. 
(Default setting is 1 second.)
Abnormalities can be detected more quickly by setting 
the response time to 0.05 seconds.
The effect of fluctuation and flickering of the display can 
be reduced by setting the response time to 2 seconds.

0.05 sec.

0.1 sec.
0.5 sec.

1 sec.
2 sec.

285

PFM

PFMV

PFMB

PFMC

PF2A

PF3W

PF2D

LFE

IF

PFMC

Содержание PFMC Series

Страница 1: ...Current PF2A 5 L min 1 L min Wide range of flow measurement with one product Compared with the current PF2A IP65 Compact Space saving Flow ratio 78 reduction Weight 74 reduction Setting resolution 10...

Страница 2: ...dication shows the operating flow rate or residual amount of N2 etc in a gas cylinder Flow control of equipment main line and branch line Applications Remote control is possible with accumulated pulse...

Страница 3: ...method Applicable fluid Thermal type MEMS Thermal type MEMS Air N2 Air N2 Argon CO2 Dry air N2 0 1 L min 0 5 L min 1 L min 2 L min 5 L min 5 L min 10 L min Thermal type MEMS Bypass flow type Thermal...

Страница 4: ...o 50 C 12 to 24 VDC 10 12 to 24 VDC 10 1 to 10 L min 5 to 50 L min 10 to 100 L min 20 to 200 L min 50 to 500 L min 150 to 3000 L min 300 to 6000 L min 600 to 12000 L min PFMB Digital IP40 2 color LCD...

Страница 5: ...5 M SI unit only Note 6 Note 5 Since the unit for Japan is fixed to SI due to new measurement law this option is for overseas Note 6 Fixed unit Instantaneous flow L min Accumulated flow L Calibration...

Страница 6: ...25 to 525 L min Displays 0 when value is within 4 to 4 L min range 50 to 1050 L min Displays 0 when value is within 9 to 9 L min range 100 to 2100 L min Displays 0 when value is within 19 to 19 L min...

Страница 7: ...a straight section of piping with a length of 8 cm or more If a straight section of piping is not installed the accuracy can vary by approximately 2 F S Straight section means a part of the piping wit...

Страница 8: ...or solid state input for 30 msec or longer NPN 1 output Analog 1 to 5 V output type PFMC7 C NPN 1 output Analog 4 to 20 mA output type PFMC7 D Max applied voltage 28 V Max load current 80 mA Internal...

Страница 9: ...ctifier Stainless steel 304 4 Sensor chip Silicon 5 Printed circuit board GE4F 6 Gasket HNBR 7 Body Aluminum alloy Anodized 8 Mesh Stainless steel 304 9 Spacer PPS 10 O ring HNBR 11 Holder Stainless s...

Страница 10: ...ue Sheath Material Heat and oil resistant PVC Finished outside diameter 4 Symbol Model Port size A B D E F H K L N PFMC7501 7102 Rc1 2 NPT1 2 70 30 60 6 41 2 15 14 26 18 13 6 PFMC7202 Rc3 4 NPT3 4 G3...

Страница 11: ...fixed state when starting the system or during maintenance This enables confirmation of the wiring and prevents system errors due to unexpected output For the analog output type when ON the output wi...

Страница 12: ...ntents Action OUT1 over current error Load current of 80 mA or more is applied to the switch output OUT1 Eliminate the cause of the over current by turning off the power supply and then turn on it aga...

Отзывы: