-66-
No.PF
※※
-OMM0005-N
Fault
Detail
Possible cause
Item to check
Recommended action
Improper
operation
of the
external
input.
No reaction
to the
external
Input.
Incorrect wiring
Check if the brown wire DC(+), blue
wire DC(-), black wire(OUT1) and white
wire(OUT2) are connected correctly.
Correct the wiring.
The input duration
is too short.
Confirm whether the input line is
connected to GND for a minimum of 30
msec.
When the external input is
applied, the input line must
be connected to GND for a
minimum of 30 msec.
Incorrect
temp.
sensor
displays.
The temp. is
not
displayed.
Setting condition
of the sub screen
Check the content of the sub screen.
Set the sub screen to the
temperature display.
Connector loose
Check that the connector is connected.
Connect the connector.
Incorrect
display
Insufficient water
supply
Confirm whether the fluid path is full.
Fill up the fluid path.
Foreign matter
Check if foreign matter is stuck to the
sensor.
Remove foreign matter.
Incorrect
temp.
sensor
output.
Output is
unstable.
Insufficient water
supply
Confirm whether the fluid path is full.
Fill up the fluid path.
Foreign matter
Check if foreign matter is stuck to the
sensor.
Remove foreign matter.
Improper
operation
of the flow
adjustment
valve.
It is not
possible to
adjust with
flow
adjustment
valve.
Lock the flow
adjustment valve
Check the condition of the flow
adjustment valve and its lock ring.
Loose the lock ring and
adjust flow rate. (Refer to
page
Insufficient supply
pressure
Check flow rate characteristics of the
supply pressure and flow rate
adjustment valve.
Increase supply pressure.
Содержание PF3W7 Series
Страница 12: ...11 No PF OMM0005 N Model Indication and How to Order Metal piping...
Страница 13: ...12 No PF OMM0005 N Polyvinyl chloride piping...
Страница 45: ...44 No PF OMM0005 N List of output modes for fluid temperature...
Страница 48: ...47 No PF OMM0005 N Example of display of sub screen...
Страница 49: ...48 No PF OMM0005 N Example of display of sub screen continued...
Страница 76: ...75 No PF OMM0005 N Characteristics graph Measurable range of ethylene glycol aqueous solution Reference value...
Страница 78: ...77 No PF OMM0005 N PF3W711 Vinyl chloride piping PF3W721 Vinyl chloride piping...
Страница 81: ...80 No PF OMM0005 N PF3W721 Metal attachment...
Страница 83: ...82 No PF OMM0005 N Flow characteristics of the flow rate adjustment valve PF3W704S PF3W720S PF3W740S...
Страница 91: ...90 No PF OMM0005 N Dimensions of rotating part of display Dimensions of lead wire with M8 connector ZS 40 A...