SMC Networks PAF5410 Скачать руководство пользователя страница 1

 

PAB-OM-K007 

 
 
 
 
 

 

 
 
 
 
 

Operation Manual 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

 

 
 
 
 
 
 
 

Process pump 

PAF5410 

Содержание PAF5410

Страница 1: ...PAB OM K007 Operation Manual Process pump PAF5410...

Страница 2: ...arge capability P7 to 8 8 Troubleshooting P9 to 10 9 Operating principle P11 Safety instructions This operation manual indicates the precautions for safety use of process pump with the level of potent...

Страница 3: ...refrigerating air dryer AM mist separator AMD micro mist separator PAF If the amount of foreign materials generated from air supply carbon powder etc is large mount super mist separator etc to reinfor...

Страница 4: ...port Suction port FLUID IN To suck transported fluid Connect suction piping Discharge port FLUID OUT To discharge fluid sucked inside the pump Connect discharge piping Air supply port AIR SUP Supply...

Страница 5: ...ump it is necessary to check leakage of fluid and air and operating condition periodically If any abnormality or concern is seen stop the pump immediately and contact local supplier or SMC When touchi...

Страница 6: ...A PTFE Discharge amount 5 to 45L min Average discharge pressure 0 to 0 4MPa Pilot air consumption Max 300L min ANR Note 2 Dry Max 1m Inside of the pump is dry Suction head Wet Max 4m The pump contains...

Страница 7: ...size side OUT side Symbol 19 1925 2519 25 5 6 5 6 6 5 Thread type Symbol Type Nill Fitting type With silencer N Actuation Thread type Option Nill Nill None 0 Automatically operated Symbol Type Symbol...

Страница 8: ...r fresh water viscosity 1mPa s specific gravity 1 0 Thus if the fluid with higher viscosity such as oil is used convert the fluid to fresh water with reference to viscosity characteristic graph The di...

Страница 9: ...fresh water Since discharge rate 45 of fresh water is equal to 9L min of the fluid with the following calculation 9L min 0 45 20L min it is found discharge rate 10L min is necessary for fresh water 3...

Страница 10: ...cement of pilot air switching part Review of piping at suction or discharge side and removal of restrictor Replacement of pump Supply of air at adequate pressure Cleaning Replacement of pump The pump...

Страница 11: ...Cleaning or replacement Cleaning or replacement Supply of air at adequate pressure Increase of air supply Removal of back pressure or increase of supplied air pressure 4 A lot of air bubble come out...

Страница 12: ...control valve is shifted and starts reverse operation Fig 2 This repeated operation realizes continuous suction and discharge Actuating chamber A Actuating chamber B Discharge port Pump chamber B Pum...