![SMC Networks PA3313 Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/smc-networks/pa3313-series/pa3313-series_operation-manual_1301103016.webp)
15
Working Principle
1. When air is supplied to P1 port, it enters drive chamber A.
2. Diaphragm A moves to the left, and at the same time diaphragm B also moves to the left.
3. The fluid in pump chamber A is forced out to the discharge port, and the fluid is sucked into pump
chamber B from the suction port.
4. If air is supplied to the P2 port, the opposite will occur. Continuous suction and discharge of fluid
is performed by repeating this process with the control of an external solenoid valve (5 port valve).
Maintenance Parts
- I
t is not recommended to disassemble the process pump. However, if this is necessary,
be sure to follow the instructions in the maintenance procedure.
-
When carrying out this work, wear appropriate protective equipment.
Description
PA3313
PAP3313
Diaphragm kit
KT-PA3-531
KT-PAP3-531
Check valve kit
KT-PA3-536#1
KT-PAP3-536#1
Foot kit
KT-PA3-40
KT-PAP3-40
The maintenance procedure is to be distributed individually. Please contact your SMC sales representative
for details.
Air supply port
(AIR SUP)
Discharge port (FLUID OUT)
Suction port (FLUID IN)
Pump chamber A
Check valve
Drive chamber B
Pump chamber B
Drive chamber A
Diaphragm A
Diaphragm B
Shaft
5 port solenoid valves
P1
P2