![SMC Networks MSQB1 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/smc-networks/msqb1/msqb1_operation-manual_1300525026.webp)
Piping
Figure 4 and Table 8 show locations and sizes of piping ports.
Ports can be selected from two sides. Plug the ports that are not used.
Table 8 Port size
Size
Port size
Front port
Side port
1
M3x0.5
2
3
7
M5x0.8
Rotary table ports have a fixed orifice. Do not make the diameter of this hole larger by additional
processing.
If the hole diameter is made larger, rotation speed and impact will increase, which may cause breakage of
the product.
Preparation before piping.
a) Before piping is connected, it should be thoroughly blown out with air to remove dust and scale from
inside the pipe. Dust and scale on the inlet side of the filter can be removed, but those on the outlet side
cannot be removed, so they can enter the solenoid valve or rotary table, which causes malfunction or
shortens product life.
b) When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material
do not enter the piping. Also, if pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the
threads.
Air supply
Air supplied to the rotary actuator shall be cleaned by the filter.
MSQ series is lubrication free.
- 25 -
Fig. 4
Fig. 5 Wrapping of pipe tape
Sealant tape
Winding
Expose approx. 2 threads
direction
Port A
Port B
Port A
Port B
2020-10-13 10:38
DI987004