- 19 -
Operation time adjustment method for holding / releasing the workpiece
The piston operation time during workpiece holding / release can be adjusted by adjusting the
opening of the metering speed controller valve.
* (1) Workpiece holding time: Time required when the piston and magnet travel from the workpiece
release position to the workpiece holding position
* (2) Workpiece release time: Time required when the piston and magnet travel from the workpiece
holding position to the workpiece release position
* Use a flat blade screwdriver for adjusting the restriction of the metering valves.
* Keep the restriction of the two metering valves approximately the same. If they are different too much,
the operation may become unstable.
Magnet gripper workpiece holding / release time
Metering valve for adjusting the
time to move to the workpiece
holding position.
Metering valve for adjusting the
time to move to the workpiece
releasing position.
(2)
Magnet
Piston
(1)
Workpiece
holding position
Workpiece
release position
Magnified view of the metering valve
Adjustment groove
(*for flat blade screwdriver
Blade width 0.7mm)
Содержание MHM-25D-X7400A-CRX
Страница 7: ... 6 3 Product Specifications 3 1 How to order ...
Страница 11: ... 10 3 4 Dimensions Refer to P13 P14 and P15 for the dimensions of the magnet gripper valves and auto switches ...
Страница 13: ... 12 3 6 Centor of gravity Center of gravity mm X Y Z 2 4 0 0 42 6 Y Z Y X X Z Flange mounting surface ...