- 17 -
5. Maintenance
5-1 Maintenance or inspection
Warning
1. Perform maintenance and inspection according to the procedures indicated in the operation
manual.
If handled improperly, human injury and/or malfunction or damage of machinery and equipment may occur.
2. Maintenance work
If handled improperly, compressed air can be dangerous. Assembly, handling, repair, and element
replacement of pneumatic systems should be performed by a knowledgeable and experienced person.
3. Drain flushing
Remove drainage from air filters regularly.
4. Removal of equipment, and supply/exhaust of compressed air
Before components are removed, first confirm that measures are in place to prevent workpieces from
dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all
compressed air from the system using the residual pressure release function. When machinery is restarted,
proceed with caution after confirming that appropriate measures are in place to prevent sudden movement.
5-2 replacement part
Caution
1) When mounting the adapter for central mounting type, tighten it at an appropriate torque using the
accessory bolts.
Tightening with a torque greater than the specified torque can cause malfunction, while insufficient
tightening can cause slippage and dropping.
Model
Adapter for Central
Mounting Type
Applicable
bolt
Tightening
torque (N
・
m)
MHM-16D
□
MHM-A1612
M3x0.5
0.63
MHM-25D
□
MHM-A2512
M4x0.7
1.5
MHM-32D
□
MHM-A3212
M5x0.8
3
MHM-50D
□
MHM-A5012
M6x1
5.2
Mounting to the basic type