-23-
15. When the table operates, the gap can be done between actuator (figure below arrow part).Do
not place the hand and the finger, etc. because it is dangerous and do not crowd.
16. The product should be mounted as shown below in the figures marked with the
○
.
Unstable mounting of the product may cause operation failure, generation of abnormal noise or
increase in the deflection etc.
17. Even with the same product number, the table of some products can be moved by hand
and the table of some products cannot be moved by hand. However, there is no
abnormality with these products. (Without lock)
This difference is caused because there is a little variation with the positive efficiency (when the table
is moved by the motor) and there is a large variation with the reverse-efficiency (when the table is
moved manually) due to the product characteristics. There is no any differences among products
when they are operated by the motor.
3.3 Precaution on maintenance
Warning
1. Turn off the power supply before maintenance and replacement of the product.
2. Put on protective goggles when applying grease.
3. For maintenance and inspection, please check the following requirements before
implementing.
[Maintenance frequency]
Perform maintenance according to the table below.
Appearance check
Check belt
Inspection before daily operation
○
-
Inspection every six months *
-
○
Inspection every 250km *
-
○
Inspection are every five million times *
-
○
*
Either of inspection early time is selected.
○
×
○
○
×
×