-4-
(3) Power supply plug
(7) Controller
setting kit
Communication
cable
PC
(2) Controller
1. Procedure before operation/simple setting to use straight away
The controller is shipped with the parameters appropriate to the actuator.
With the simple setting “easy mode”, it can be operated and running parameters can be changed easily.
1.1 Preparation
(1) Items to be prepared
Please check on the label,
and the quantity of accessories, to confirm that it is the product that was
ordered.
Table 1. Components
No.
Part name
Qty
(1)
Electric actuator / Guide rod Slider
1
(2)
Controller
1
(3)
Power supply plug
1
(4)
Actuator cable
1
(5)
I/O cable (Not use in this section)
1
(6)
Teaching box
1
(7)
Controller setting kit
[The controller setting software, The communication cable, USB cable and conversion unit are included.]
1
Table 2. Items to be prepared by the customer
Part name
Conditions
Power supply 24VDC
Do not use the power supply
with “Inrush-restraining type”
Refer to power consumption of each actuator/See 2.1Specification on page
9
(Prepare the power supply that has capacity of “Moment max.
power consumption” or more.)
Wire AWG20 (0.5mm
2
)
Power supply plug
Wiring
Connect the plus side of 24VDC to the C24V, M24V and EMG terminals of
the power supply plug, and the minus side to the 0V terminal. When
conformity to UL is required, the electric actuator and controller should be
used with a UL1310 Class 2 power supply.
Option
(4) Actuator cable
To USB port
(6) Teaching Box
To CN1
To CN2
To CN3
To CN4
(1) Electric actuator
/Guide rod Slider
or
Stripped wire length
8mm
Step motor
(
servo 24VDC
)
Electrical
wire entry
Push the open/close lever and insert the wire into the electrical wire entry
24VDC
power
suppiy
24V
0V
M24V
0V
EMG
C24V