3 Installation 

3.1  Installation 

 Warning 

  Do  not  install  the  product  unless  the  safety  instructions  have  been 

read and understood. 

  Do  not  use  the  product  in  excess  of  its  allowable  specification  as 

listed in Section 2. 

  When installing, inspecting or performing maintenance on the product, 

be  sure  to  turn  off  the  power  supplies.  Then,  lock  it  so  it  cannot  be 
tampered with while work is happening.  

  Keep the flatness of the mounting surface to 0.1 mm maximum. 

Insufficient flatness of a work piece or actuator mounting surface can 
cause play in the guide and increased sliding resistance. In the case 
of  overhang  mounting  (including  cantilever),  use  a  support  plate  or 
support guide to avoid deflection of the actuator body. 

  When mounting the actuator, use all mounting holes. 

If all mounting holes are not used, this will not maintain the specified 
performance.  e.g.  the  amount  of  displacement  of  the  table  will 
increase. 

  When  mounting  the  actuator,  use  screws  with  adequate  length  and 

tighten them with adequate torque. 
Tightening  the  screws  with  a  torque  higher  than  recommended  may 
cause  malfunction,  whilst  tightening  with  a  torque  lower  than 
recommended can cause displacement of the mounting position, or in 
extreme  conditions  the  actuator  could  become  detached  from  its 
mounting position. 

 

 

 

 

Note1) When A is M thread, L is thread depth. 

 

 

 

 

 

 

  In  order  to  prevent  the  work  piece  fixing  screws  from  damaging  the 

table,  use screws  at least  0.5 mm shorter  than  the maximum thread 
depth. 
Longer screws can hit the body and cause operation failure. 

  When  mounting  the  actuator  using  the  body  mounting  reference 

plane, use a positioning pin. 
Set  the  height  of  the  pin  to  be  5  mm  or  more  because  of  R 
chamfering. (recommended height: 6 mm). 

 

 

 

 

 

 

 

 

 

 

3 Installation - continued 

3.2  Environment 

 Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result 

in temperatures in excess of the product’s specifications. 

  Prevent foreign particles from entering the product. 

 
3.3  Mounting 

Warning 

  Observe the required tightening torque for screws. 

Unless  stated  otherwise,  tighten  the  screws  to  the  recommended 
torque for mounting the product.  

  Do not make any alterations to the product. 

Alterations made to  this  product may lead  to  a  loss  of  durability  and 
damage to the product, which can lead to injury and damage to other 
equipment and machinery. 

  When  an  external  guide  is  used,  connect  the  moving  parts  of  the 

product  and  the  load  in  such  a  way  that  there  is  no  interference  at 
any point within the stroke. 
Do not scratch or dent the sliding parts of the table or mounting face 
etc.,  by striking  or  holding  them with  other  objects.  The components 
are  manufactured  to  precise  tolerances,  so  that  even  a  slight 
deformation may cause faulty operation or seizure. 

  Do  not  use  the  product  until  it  has  been  verified  that  the  equipment 

can be operated correctly. 
After mounting or repair, connect the power supply to the product and 
perform  appropriate  functional  inspections  to  check  it  is  mounted 
correctly.  

  Do  not  use  the  product  until  it  has  been  verified  that  the  equipment 

can be operated correctly. 
After mounting or repair, connect the power supply to the product and 

perform  appropriate  functional  inspections  to  check  it  is  mounted 
correctly.  

  Maintenance space 

Allow sufficient space for maintenance and inspection. 

 

3.4  Lubrication 

Caution 

  SMC  products  have  been  lubricated  for  life  at  manufacture,  and  do 

not require lubrication in service. 

  If a lubricant is used in the system, refer to catalogue for details. 

  The recommended grease is lithium grade No.2 

SMC grease packs are listed below. 

Applied Region 

Grease Pack Number 

Weight [g] 

Ball screw 

Guide 

Dust seal band 

GR-S-010 

10 

GR-S-020 

20 

 

3.5  Wiring  

Warning 

  Adjustment,  mounting  or  wiring  changes  should  not  be  carried  out 

before disconnecting the power supply to the product. 
Electric shock, malfunction and damage can result. 

  Do not disassemble the cables.  

  Use only specified cables. 

Use  only  specified  cables  otherwise  there  may  be  risk  of  fire  and 
damage. 

  Do not connect or disconnect the wires, cables and connectors when 

the power is turned on. 

Caution 

  Wire the connector correctly and securely.  

Check the connector for polarity and do not apply any voltage to the 
terminals other than those specified in the Operation Manual.  

3 Installation - continued 

  Take appropriate measures against noise. 

Noise  in  a  signal  line  may  cause  malfunction.  As  a  countermeasure 
separate  the  high  voltage  and  low  voltage  cables,  and  shorten  the 
wiring lengths, etc.  

  Do  not  route  input/output  wires  and  cables  together  with  power  or 

high voltage cables. 
The  product  can  malfunction  due  to  noise  interference  and  surge 
voltage  from  power  and  high  voltage  cables  close  to  the  signal  line. 
Route the wires of the product separately from power or high voltage 
cables.  

  Take care that actuator movement does not catch cables. 

  Operate with all wires and cables secured.  

  Avoid bending cables at sharp angles where they enter the product. 

  Avoid  twisting,  folding,  rotating  or  applying  an  external  force  to  the 

cable.  
Risk  of  electric  shock,  wire  breakage,  contact  failure  and  loss  of 
control of the product can result.  

  Select 

“Robotic  cables”  in  applications  where  cables  are  moving 

repeatedly (encoder/ motor/ lock). 

 

Refer  to  the  relevant  operation  manual  for  the  bending  life  of  the 

cable. 

  Confirm correct insulation. 

Poor insulation of wires, cables, connectors, terminals etc. can cause 
interference  with  other  circuits.  Also  there  is  the  possibility  that 
excessive  voltage  or  current  may  be  applied  to  the  product  causing 
damage. 

  R

efer  to  the  auto  switch  references  in  “Best  Pneumatics“  when  an 

auto switch is to be used

 

 
 
 
 
 
 
 

 

LECSA (Pulse input / Positioning) driver 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3 Installation - continued 

 

 

 

 

 

 

 

 

 

 

3.6  Operating precautions 

  Do  not  touch  the  motor  whilst  it  is  in  operation.  The  surface 

temperature  can  increase  to  approximately  80°C.  Energising  alone 
can  also  increase  the  temperature  of  the  product.  These 
temperatures can cause burns. 

  If the product is overheating, smoking or has caught fire, immediately 

shut the power supply off. 

  If the product emits abnormal noise or vibrations, the product should 

be  immediately  stopped  and  inspected  as  it  may  be  mounted 
incorrectly, otherwise it can seriously damage the product. 

  Do  not  touch  rotating  parts  of  the  motor  or  moving  parts  of  the 

actuator while in operation. 

 

 

4 How to Order 

  For  standard  products,  refer  to  the  catalogue  for  the  how  to  order 

information. 

 

For special products, which include a suffix of “-X*”, “-DC*” or “-DK*”, 
then please refer to the customer drawing of that specific product. 

 

5 Outline Dimensions (mm) 

  For standard products, refer to the catalogue for outline dimensions. 

 

For special products, which include a suffix of “-X*”, “-DC*” or “-DK*”, 
then please refer to the customer drawing of that specific product. 

 

6 Maintenance 

6.1  General Maintenance 

Caution 

  Not  following  proper  maintenance  procedures  could  cause  the 

product to malfunction and lead to equipment damage. 

  If handled improperly, compressed air can be dangerous. 

  Maintenance  of  pneumatic  systems  should  be  performed  only  by 

qualified personnel. 

  Before  performing  maintenance,  turn  off  the  power  supply  and  be 

sure to cut off the supply pressure. Confirm that the air is released to 
atmosphere. 

  After  installation  and  maintenance,  apply  operating  pressure  and 

power  to  the  equipment  and  perform  appropriate  functional  and 
leakage tests to make sure the equipment is installed correctly. 

  If  any  electrical  connections  are  disturbed  during  maintenance, 

ensure they are reconnected correctly and safety checks are carried 
out  as  required  to  ensure  continued  compliance  with  applicable 
national regulations. 

  Do not make any modification to the product. 

  Do  not  disassemble  the  product,  unless  required  by  installation  or 

maintenance instructions. 

 

I

ncorrect handling can cause an injury, damage or malfunction of the 

equipment and machinery, so ensure that the procedure for the task 
is followed. 

  Always  allow  sufficient  space  around  the  product  to  complete  any 

maintenance and inspection.  

 

 

 

Model 

Screw size 

Maximum tightening 

torque (Nm) 

A (mm) 

L (mm)

Note1)

 

LEJ

40 

M5 

3.0 

φ

5.5 

36.5 

LEJ

63 

M6 

5.2 

φ

6.8 

49.5 

LEJS100 

M8 x 1.25 

12.5 

M8 

16 

Model 

Screw size 

Maximum tightening 

torque (Nm) 

L (Maximum thread 

depth) mm 

LEJ

40 

M6 x 1 

5.2 

10 

LEJ

63 

M8 x 1.25 

12.5 

12 

LEJS100 

M8 x 1.25 

12.5 

16 

Driver 

Motor cable

 

Encoder cable

 

Electric actuator

 

24 
VDC 

Lock cable

 

Host 
controller 
etc. 

I/O connector

 

LECSB / LECSB-T (Pulse input) driver 
LECSC / LECSC-T (CC-Link) driver 
LECSS / LECSS-T (SSCNET) driver 

 

 

LECYM / LECYU (MECHATROLINK) driver 

 

Driver 

Motor cable 

(With Lock cable)

 

 

 

Encoder cable

 

Electric actuator

 

Host 
controller 
etc. 

I/O connector

 

24 
VDC 
 

Actuator mounting 

Work piece mounting 

Mounting reference plane 

Driver 

Motor cable

 

Encoder cable

 

Electric actuator

 

24 
VDC 
 

Host 
controller 
etc. 

I/O connector

 

Lock cable

 

Отзывы: