6.2 Alarm History Display (Fn000)
This function displays the last ten alarms that have occurred in the DRIVER. The latest ten alarm numbers and
time stamps* can be checked.
∗
Time Stamps
A function that measures the ON times of the control power supply and main circuit power supply in 100-ms units
and displays the total operating time when an alarm occurs. The time stamp operates around the clock for
approximately 13 years.
<Example of Time Stamps>
If 36000 is displayed,
3600000 [ms] = 3600 [s] = 60 [min] = 1 [h]
Therefore, the total number of operating hours is 1 hour.
(1) Preparation
There are no tasks that must be performed before displaying the alarm history.
(2) Operating Procedure
In the S
Σ
-V component main window, click
Alarm
and then click
Display Alarm
.
Click Alarm Traceback tab page, and are shown in order of occurrence with alarm codes and details about
the type of alarm, such as name.
For more information on the usage of the S, refer to AC Servo Drives Engineering Tool Sigma
Win+ ONLINE MANUAL Σ-V Component
4.2 Alarm Display
.
Note:
・
If the same alarm occurs after more than one hour, the alarm will be saved. If it occurs in less than one
hour, it will not be saved.
・
Click
Clear
to delete or clear the alarm history. The alarm history is not cleared on alarm reset or
when the DRIVER main circuit power is turned OFF.
Содержание LECYU Series
Страница 30: ...1 Outline 1 9 1 4 3 Three phase 200 V LECYU2 V9 Models ...
Страница 65: ...3 Wiring and Connection 3 11 3 Wiring Example with DC Power Supply Input DRIVER ...
Страница 92: ...3 Wiring and Connection 3 38 External Dimensions Units mm 1 FN Type by Schaffner EMC Inc ...
Страница 93: ...3 Wiring and Connection 3 39 2 FN Type ...
Страница 99: ...3 Wiring and Connection 3 45 4 Cable with Connector for CN8 Model LEC JZ CVSAF External Dimensions Units mm ...
Страница 143: ...4 Operation 4 44 ...