- 9 -
(4) Power supply ON
Alarm check
Supply power 24V DC.
Description
LED turns on
Condition
Green LED is on
Servo is on
PWR
Green LED is flashing
Servo is turned off
ALARM
Red
Alarm is generated
If the conditions are normal, the LED[PWR] at the front of the controller switches from a flashing to a
solid light. The servo is turned on if the conditions are normal. If the LED[ALM] on the front surface of
the controller turns red, the alarm goes off.
Caution
When an alarm is generated
Confirm the content of the alarm with 7-segment LED of the controller or I/O output.
Eliminate the cause referring to
.
(5) Data (Operation pattern) setting
Set the stop position, speed, acceleration, and deceleration for the operating directions with the
buttons and switches on the controller. Operations other than position setting, jog/inching can be
performed after returning to origin position. Refer to
for the details of
settings.
(6) Test run
Test run is performed with the buttons and switches of the controller or I/O signal. Refer to
and
6.3 Parallel input / output signal (P.20)
for details.
Controller