- 23 -
7. Setting method
It is necessary to set the stop position and operation method using the controller in order to move the
actuator to the specified position. Set data is stored in the memory in the controller
Up to 14 points can be set. Set "1" to "14" with the position switch
○
h . ("1" to "9", "A" to "E") is
displayed in hexadecimal on the 7-segment LED
○
f .
There are 2 types of modes on the controller (manual mode, auto mode).
Setting and operating methods are different. Mode is switched by mode
Switch
○
e .
Upper part of the right figure(M) : Manual mode
Lower part of the right figure(A) : Auto mode
Caution
Close the cover
○
c after the switching the mode to avoid
unexpected mode changes.
Manual mode(M)
Auto mode(A)
Setting of stop position (step
data)
O X
Setting of Speed and
Acceleration
O
∆
(Only in speed
adjustment)*2
Setting of operation method
O X
Setting parameters
O X
Controller operation using the
button
O X
Operation from parallel I/O
X O
Positioning operation
O O
Pushing operation
∆
(Test function only)*1
O
Output to parallel I/O
∆
(Test function only)*1
O
Check the presence of alarm
O
O
Check the content of alarm
O O
How to release the alarm
Press set button
○
g
Turn on RESET or
press set button
○
g
Servo OFF method
Turn off Servo Press
Forward button
○
i
and Reverse button
○
j simultaneously for
3 sec.
Turn on STOP
for details of test function.
for details of the adjustment of the speed.
○
f
○
e
○
c
○
i
○
g
○
h
○
j